Solar panels, heat pumps and insulation in Myrdle Street (7464) conservation area

In the Myrdle Street conservation area (Tower Hamlets), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Tower Hamlets covers part of this area (about 17% of it), but the published data does not say which rights it removes — check the direction before any work. The area has 18 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 802 homes inside the boundary have an energy certificate: 57.7% are solid-wall homes with no wall insulation, 71.8% heat with a gas boiler and 37.3% are rated D–G; 12 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

802homes with an energy certificate
57.7%solid walls, no insulation
71.8%heated by a gas boiler
12heat pumps

Article 4: An Article 4 direction published by Tower Hamlets covers part of this area (about 17% of it), but the published data does not say which rights it removes — check the direction before any work. (Whitechapel 2)

What needs planning permission in Myrdle Street

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 802)

WallsHomesShare
Solid wall (brick or stone), no insulation46357.7%
Solid wall, insulated11714.6%
Cavity wall, insulated (as built or unspecified)9612.0%
Modern wall (U-value from the design)556.9%
Timber frame364.5%
Other or not known131.6%
Solid wall, partly insulated70.9%
Cavity wall, unfilled60.7%
Solid wall, internal insulation60.7%
Cavity wall, filled20.2%
Cavity wall, internal or external insulation10.1%
HeatingHomesShare
Gas boiler57671.8%
Electric (storage heaters, panels, boiler)20425.4%
Heat pump121.5%
Communal heating101.2%
Loft / roof insulationHomesShare
No insulation11814.7%
Under 200 mm364.5%
200 mm or more273.4%
Insulated (depth not recorded)9612.0%
Flat or other home above48961.0%
Other364.5%
WindowsHomesShare
Double glazed63278.8%
Single glazed14017.5%
Secondary glazing293.6%
Triple glazed10.1%

Energy rating: B 65 (8.1%) · C 438 (54.6%) · D 240 (29.9%) · E 53 (6.6%) · F 2 (0.2%) · G 4 (0.5%). Houses and bungalows: 11% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1900-1929.

Compared with Tower Hamlets and England

Share of homesMyrdle StreetAll 61 areas in Tower HamletsEngland
Solid walls, no insulation57.7%41.8%48.7%
Gas boiler71.8%61.1%66.4%
Rated D–G37.3%—56.5%