Solar panels, heat pumps and insulation in Carlton Square conservation area

In the Carlton Square conservation area (Tower Hamlets), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Tower Hamlets covers part of this area (about 3% of it), but the published data does not say which rights it removes — check the direction before any work. The area has 6 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 338 homes inside the boundary have an energy certificate: 68.9% are solid-wall homes with no wall insulation, 89.9% heat with a gas boiler and 68.3% are rated D–G; 1 has a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

338homes with an energy certificate
68.9%solid walls, no insulation
89.9%heated by a gas boiler
1heat pumps

Article 4: An Article 4 direction published by Tower Hamlets covers part of this area (about 3% of it), but the published data does not say which rights it removes — check the direction before any work. (Stepney Green 3)

What needs planning permission in Carlton Square

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 338)

WallsHomesShare
Solid wall (brick or stone), no insulation23368.9%
Cavity wall, unfilled3510.4%
Cavity wall, insulated (as built or unspecified)236.8%
Modern wall (U-value from the design)164.7%
Cavity wall, filled113.3%
Cavity wall, partly insulated72.1%
Solid wall, insulated41.2%
Solid wall, internal insulation41.2%
Solid wall, partly insulated20.6%
Timber frame20.6%
Cavity wall, internal or external insulation10.3%
HeatingHomesShare
Gas boiler30489.9%
Electric (storage heaters, panels, boiler)339.8%
Heat pump10.3%
Loft / roof insulationHomesShare
No insulation11634.3%
Under 200 mm6920.4%
200 mm or more329.5%
Insulated (depth not recorded)319.2%
Flat or other home above7421.9%
Other164.7%
WindowsHomesShare
Double glazed27380.8%
Single glazed6418.9%
Secondary glazing10.3%

Energy rating: A 1 (0.3%) · B 11 (3.3%) · C 95 (28.1%) · D 196 (58.0%) · E 31 (9.2%) · F 2 (0.6%) · G 2 (0.6%). Houses and bungalows: 56% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900.

Compared with Tower Hamlets and England

Share of homesCarlton SquareAll 61 areas in Tower HamletsEngland
Solid walls, no insulation68.9%41.8%48.7%
Gas boiler89.9%61.1%66.4%
Rated D–G68.3%—56.5%

Caveats

All conservation areas in Tower Hamlets · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker