EPC Price Check

Solar panels, heat pumps and insulation in Artillery Passage conservation area

In the Artillery Passage conservation area (Tower Hamlets), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Tower Hamlets covers this area, but the published data does not say which rights it removes — check the direction before any work. The area has 23 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 206 homes inside the boundary have an energy certificate: 31.6% are solid-wall homes with no wall insulation, 54.4% heat with a gas boiler and 27.2% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

206homes with an energy certificate
31.6%solid walls, no insulation
54.4%heated by a gas boiler
0heat pumps

Article 4: An Article 4 direction published by Tower Hamlets covers this area, but the published data does not say which rights it removes — check the direction before any work. (Artillery Lane)

What needs planning permission in Artillery Passage

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 206)

WallsHomesShare
Cavity wall, insulated (as built or unspecified)9043.7%
Solid wall (brick or stone), no insulation6531.6%
Modern wall (U-value from the design)188.7%
Other or not known157.3%
Cavity wall, unfilled41.9%
Solid wall, insulated41.9%
Solid wall, internal insulation41.9%
Timber frame41.9%
Cavity wall, partly insulated21.0%
HeatingHomesShare
Gas boiler11254.4%
Electric (storage heaters, panels, boiler)9244.7%
Communal heating10.5%
LPG10.5%
Loft / roof insulationHomesShare
No insulation188.7%
Under 200 mm10.5%
200 mm or more10.5%
Insulated (depth not recorded)3818.4%
Flat or other home above14268.9%
Other62.9%
WindowsHomesShare
Double glazed17986.9%
Single glazed2210.7%
Secondary glazing52.4%

Energy rating: B 62 (30.1%) · C 88 (42.7%) · D 43 (20.9%) · E 12 (5.8%) · F 1 (0.5%). Houses and bungalows: 3% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 2003-2006. Designated: 1 January 1975.

Compared with Tower Hamlets and England

Share of homesArtillery PassageAll 61 areas in Tower HamletsEngland
Solid walls, no insulation31.6%41.8%48.7%
Gas boiler54.4%61.1%66.4%
Rated D–G27.2%—56.5%

Caveats

All conservation areas in Tower Hamlets · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker