EPC Price Check

Solar panels, heat pumps and insulation in Albert Gardens conservation area

In the Albert Gardens conservation area (Tower Hamlets), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 19 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 500 homes inside the boundary have an energy certificate: 52.6% are solid-wall homes with no wall insulation, 80.8% heat with a gas boiler and 40.2% are rated D–G; 6 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

500homes with an energy certificate
52.6%solid walls, no insulation
80.8%heated by a gas boiler
6heat pumps

Article 4: Tower Hamlets publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Albert Gardens

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 500)

WallsHomesShare
Solid wall (brick or stone), no insulation26352.6%
Cavity wall, insulated (as built or unspecified)8016.0%
Cavity wall, unfilled336.6%
Modern wall (U-value from the design)326.4%
Cavity wall, filled214.2%
Solid wall, external insulation193.8%
Other or not known173.4%
Cavity wall, partly insulated112.2%
Solid wall, insulated91.8%
Solid wall, internal insulation81.6%
Timber frame51.0%
Solid wall, partly insulated20.4%
HeatingHomesShare
Gas boiler40480.8%
Communal heating7615.2%
Electric (storage heaters, panels, boiler)112.2%
Heat pump61.2%
LPG30.6%
Loft / roof insulationHomesShare
No insulation7515.0%
Under 200 mm5911.8%
200 mm or more295.8%
Insulated (depth not recorded)6513.0%
Flat or other home above25050.0%
Other224.4%
WindowsHomesShare
Double glazed32965.8%
Single glazed13727.4%
Secondary glazing255.0%
Triple glazed91.8%

Energy rating: B 62 (12.4%) · C 237 (47.4%) · D 165 (33.0%) · E 34 (6.8%) · F 2 (0.4%). Houses and bungalows: 27% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 October 2008.

Compared with Tower Hamlets and England

Share of homesAlbert GardensAll 61 areas in Tower HamletsEngland
Solid walls, no insulation52.6%41.8%48.7%
Gas boiler80.8%61.1%66.4%
Rated D–G40.2%—56.5%