EPC Price Check

Solar panels, heat pumps and insulation in West Tytherley conservation area

In the West Tytherley conservation area (Test Valley), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 16 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 79 homes inside the boundary have an energy certificate: 18% are solid-wall homes with no wall insulation, 0% heat with a gas boiler and 80% are rated D–G; 16 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

79homes with an energy certificate
18%solid walls, no insulation
0%heated by a gas boiler
16heat pumps

Article 4: Test Valley does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in West Tytherley

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 79)

WallsHomesShare
Cavity wall, filled2633%
Cavity wall, unfilled1823%
Solid wall (brick or stone), no insulation1418%
Cavity wall, insulated (as built or unspecified)911%
Modern wall (U-value from the design)56%
Timber frame45%
Solid wall, internal insulation23%
Cavity wall, internal or external insulation11%
HeatingHomesShare
Oil3747%
Electric (storage heaters, panels, boiler)2025%
Heat pump1620%
LPG45%
Solid fuel (wood, coal)23%
Loft / roof insulationHomesShare
No insulation56%
Under 200 mm1418%
200 mm or more2835%
Insulated (depth not recorded)2228%
Flat or other home above45%
Other68%
WindowsHomesShare
Double glazed7494%
Single glazed34%
Secondary glazing11%
Triple glazed11%

Energy rating: B 7 (9%) · C 9 (11%) · D 29 (37%) · E 26 (33%) · F 8 (10%). Houses and bungalows: 89% of the homes; solar panels on 0% of the certificates. Most common build period on the certificates: before 1900. Designated: 24 April 1991.

Compared with Test Valley and England

Share of homesWest TytherleyAll 36 areas in Test ValleyEngland
Solid walls, no insulation18%33.7%48.7%
Gas boiler0%27.1%66.4%
Rated D–G80%—56.5%

Caveats

All conservation areas in Test Valley · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker