Solar panels, heat pumps and insulation in Ingestre conservation area

In the Ingestre conservation area (Stafford), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 9 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 31 homes inside the boundary have an energy certificate: 52% are solid-wall homes with no wall insulation, 3% heat with a gas boiler and 100% are rated D–G; 1 has a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

31homes with an energy certificate
52%solid walls, no insulation
3%heated by a gas boiler
1heat pumps

Article 4: Stafford publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Ingestre

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 31)

WallsHomesShare
Solid wall (brick or stone), no insulation1652%
Solid wall, insulated929%
Solid wall, internal insulation310%
Cavity wall, insulated (as built or unspecified)13%
Cavity wall, unfilled13%
Timber frame13%
HeatingHomesShare
Oil1548%
LPG1342%
Electric (storage heaters, panels, boiler)13%
Gas boiler13%
Heat pump13%
Loft / roof insulationHomesShare
No insulation26%
Under 200 mm516%
200 mm or more826%
Insulated (depth not recorded)1652%
WindowsHomesShare
Double glazed2787%
Single glazed413%

Energy rating: D 12 (39%) · E 14 (45%) · F 5 (16%). Houses and bungalows: 100% of the homes; solar panels on 0% of the certificates. Most common build period on the certificates: before 1900. Designated: 22 November 1970.

Compared with Stafford and England

Share of homesIngestreAll 29 areas in StaffordEngland
Solid walls, no insulation52%35.7%48.7%
Gas boiler3%58.4%66.4%
Rated D–G100%—56.5%