Solar panels, heat pumps and insulation in St Albans - Fishpool Street and St Michaels Village conservation area
In the St Albans - Fishpool Street and St Michaels Village conservation area (St Albans), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by St Albans covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. The area has 72 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 157 homes inside the boundary have an energy certificate: 55.4% are solid-wall homes with no wall insulation, 98.1% heat with a gas boiler and 72.6% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.
Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources
157homes with an energy certificate
55.4%solid walls, no insulation
98.1%heated by a gas boiler
0heat pumps
Article 4: An Article 4 direction published by St Albans covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. (Verulam and Fishpool Street)
What needs planning permission in St Albans - Fishpool Street and St Michaels Village
Work (house, not listed)
In a conservation area
Rule
Air source heat pump on a wall or roof facing the road, or nearer the road than the house
Planning permission needed
Part 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)
No permission needed (permitted development)
Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)
No permission needed (permitted development)
Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the road
Planning permission needed
Part 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)
Replacement windows and doors of similar appearance
Planning permission needed (an Article 4 direction here removes this right)
Part 1 Class A, A.3(a)
Listed buildings: 72 in the area (grade I: 0, II*: 5). The table is for houses that are not listed: on a listed building, solar panels and air source heat pumps are not permitted development at all (they need planning permission), and any of these works needs listed building consent.
Flats: 4% of the certified homes here are flats or maisonettes. Homes in a block of flats have no householder rights for alterations; heat pumps and solar have their own, tighter rules for blocks of flats.
The homes in the area (latest certificate per home, n = 157)
Walls
Homes
Share
Solid wall (brick or stone), no insulation
87
55.4%
Cavity wall, filled
19
12.1%
Timber frame
12
7.6%
Cavity wall, unfilled
11
7.0%
Cavity wall, insulated (as built or unspecified)
9
5.7%
Modern wall (U-value from the design)
8
5.1%
Solid wall, internal insulation
4
2.5%
Solid wall, insulated
3
1.9%
Cavity wall, partly insulated
2
1.3%
Cavity wall, internal or external insulation
1
0.6%
Other or not known
1
0.6%
Heating
Homes
Share
Gas boiler
154
98.1%
LPG
2
1.3%
Electric (storage heaters, panels, boiler)
1
0.6%
Loft / roof insulation
Homes
Share
No insulation
33
21.0%
Under 200 mm
35
22.3%
200 mm or more
24
15.3%
Insulated (depth not recorded)
54
34.4%
Flat or other home above
3
1.9%
Other
8
5.1%
Windows
Homes
Share
Double glazed
91
58.0%
Single glazed
52
33.1%
Secondary glazing
14
8.9%
CDE
Energy rating: A 1 (0.6%) · B 7 (4.5%) · C 35 (22.3%) · D 71 (45.2%) · E 36 (22.9%) · F 6 (3.8%) · G 1 (0.6%). Houses and bungalows: 96% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 24 March 1969.
Compared with St Albans and England
Share of homes
St Albans - Fishpool Street and St Michaels Village
All 45 areas in St Albans
England
Solid walls, no insulation
55.4%
37.1%
48.7%
Gas boiler
98.1%
76.8%
66.4%
Rated D–G
72.6%
—
56.5%
Caveats
Certificates describe a home when it was assessed; 53% of these are from 2020 or later (latest 13 October 2026). “No insulation (assumed)” is the assessor's default for older walls.
The rules are England's national permitted development rules (General Permitted Development Order 2015, Schedule 2, as at 21 October 2026). They do not cover building regulations or a council's own conditions. This is not a planning decision: ask St Albans if in doubt.
Boundary: St Albans City and District Council via planning.data.gov.uk (entity 44010098, reference CA11_4c, 21.0 ha); the council's appraisal or map. Homes are placed by the coordinates of their UPRN (OS Open UPRN); addresses are not shown.