EPC Price Check

Solar panels, heat pumps and insulation in Monkton conservation area

In the Monkton conservation area (South Tyneside), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 7 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 35 homes inside the boundary have an energy certificate: 26% are solid-wall homes with no wall insulation, 97% heat with a gas boiler and 69% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

35homes with an energy certificate
26%solid walls, no insulation
97%heated by a gas boiler
0heat pumps

Article 4: South Tyneside does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Monkton

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 35)

WallsHomesShare
Cavity wall, insulated (as built or unspecified)1440%
Solid wall (brick or stone), no insulation926%
Cavity wall, filled720%
Cavity wall, unfilled26%
Cavity wall, partly insulated13%
Solid wall, insulated13%
Solid wall, internal insulation13%
HeatingHomesShare
Gas boiler3497%
Electric (storage heaters, panels, boiler)13%
Loft / roof insulationHomesShare
No insulation411%
Under 200 mm1131%
200 mm or more1234%
Insulated (depth not recorded)823%
WindowsHomesShare
Double glazed3394%
Single glazed26%

Energy rating: C 11 (31%) · D 14 (40%) · E 4 (11%) · F 4 (11%) · G 2 (6%). Houses and bungalows: 100% of the homes; solar panels on 0% of the certificates. Most common build period on the certificates: 1983-1990. Designated: 1 January 1975.

Compared with South Tyneside and England

Share of homesMonktonAll 11 areas in South TynesideEngland
Solid walls, no insulation26%27.4%48.7%
Gas boiler97%82.4%66.4%
Rated D–G69%—56.5%

Caveats

All conservation areas in South Tyneside · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker