EPC Price Check

Solar panels, heat pumps and insulation in Colnbrook conservation area

In the Colnbrook conservation area (Slough), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 24 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 169 homes inside the boundary have an energy certificate: 30.2% are solid-wall homes with no wall insulation, 54.4% heat with a gas boiler and 60.9% are rated D–G; 5 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

169homes with an energy certificate
30.2%solid walls, no insulation
54.4%heated by a gas boiler
5heat pumps

Article 4: Slough does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Colnbrook

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 169)

WallsHomesShare
Cavity wall, insulated (as built or unspecified)6136.1%
Solid wall (brick or stone), no insulation5130.2%
Timber frame158.9%
Cavity wall, filled105.9%
Cavity wall, unfilled105.9%
Cavity wall, partly insulated74.1%
Modern wall (U-value from the design)74.1%
Solid wall, internal insulation63.6%
Cavity wall, internal or external insulation10.6%
Solid wall, insulated10.6%
HeatingHomesShare
Gas boiler9254.4%
Electric (storage heaters, panels, boiler)7041.4%
Heat pump53.0%
Communal heating21.2%
Loft / roof insulationHomesShare
No insulation169.5%
Under 200 mm5432.0%
200 mm or more2816.6%
Insulated (depth not recorded)2011.8%
Flat or other home above4828.4%
Other31.8%
WindowsHomesShare
Double glazed12775.1%
Secondary glazing3017.8%
Single glazed63.6%
Triple glazed63.6%

Energy rating: B 2 (1.2%) · C 64 (37.9%) · D 77 (45.6%) · E 23 (13.6%) · F 1 (0.6%) · G 2 (1.2%). Houses and bungalows: 46% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900.

Compared with Slough and England

Share of homesColnbrookAll 5 areas in SloughEngland
Solid walls, no insulation30.2%44.4%48.7%
Gas boiler54.4%53.1%66.4%
Rated D–G60.9%—56.5%

Caveats

All conservation areas in Slough · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker