EPC Price Check

Solar panels, heat pumps and insulation in Waterloo Park conservation area

In the Waterloo Park conservation area (Sefton), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 1 listed building; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 163 homes inside the boundary have an energy certificate: 34.4% are solid-wall homes with no wall insulation, 74.2% heat with a gas boiler and 50.3% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

163homes with an energy certificate
34.4%solid walls, no insulation
74.2%heated by a gas boiler
0heat pumps

Article 4: Sefton publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Waterloo Park

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 163)

WallsHomesShare
Modern wall (U-value from the design)5936.2%
Solid wall (brick or stone), no insulation5634.4%
Cavity wall, unfilled148.6%
Cavity wall, insulated (as built or unspecified)116.7%
Solid wall, insulated95.5%
Solid wall, internal insulation74.3%
Timber frame31.8%
Cavity wall, internal or external insulation10.6%
Cavity wall, partly insulated10.6%
Other or not known10.6%
Solid wall, partly insulated10.6%
HeatingHomesShare
Gas boiler12174.2%
Electric (storage heaters, panels, boiler)4125.2%
Communal heating10.6%
Loft / roof insulationHomesShare
No insulation127.4%
Under 200 mm127.4%
200 mm or more95.5%
Insulated (depth not recorded)84.9%
Flat or other home above9658.9%
Other2616.0%
WindowsHomesShare
Double glazed15192.6%
Single glazed127.4%

Energy rating: B 23 (14.1%) · C 58 (35.6%) · D 56 (34.4%) · E 23 (14.1%) · F 3 (1.8%). Houses and bungalows: 5% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 1 October 1991.

Compared with Sefton and England

Share of homesWaterloo ParkAll 25 areas in SeftonEngland
Solid walls, no insulation34.4%32.5%48.7%
Gas boiler74.2%70.7%66.4%
Rated D–G50.3%—56.5%

Caveats

All conservation areas in Sefton · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker