Solar panels, heat pumps and insulation in Winchelsea conservation area

In the Winchelsea conservation area (Rother), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Rother covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), painting the outside, so there these need planning permission too. The area has 99 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 182 homes inside the boundary have an energy certificate: 40.1% are solid-wall homes with no wall insulation, 85.2% heat with a gas boiler and 89.0% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

182homes with an energy certificate
40.1%solid walls, no insulation
85.2%heated by a gas boiler
0heat pumps

Article 4: An Article 4 direction published by Rother covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), painting the outside, so there these need planning permission too. (East Sussex (Battle Rural District) Direction, 1959; East Sussex (Fairlight, Pett and Icklesham) Direction, 1965; East Sussex (Winchelsea) Direction, 1970; Rother District Council (Winchelsea Conservation Area, Winchelsea, East Sussex) Article 4 Direction, 2007)

What needs planning permission in Winchelsea

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 182)

WallsHomesShare
Solid wall (brick or stone), no insulation7340.1%
Cavity wall, unfilled3921.4%
Cavity wall, filled2714.8%
Timber frame2413.2%
Cavity wall, insulated (as built or unspecified)84.4%
Solid wall, internal insulation42.2%
Cavity wall, partly insulated21.1%
Modern wall (U-value from the design)21.1%
Other or not known21.1%
Solid wall, partly insulated10.5%
HeatingHomesShare
Gas boiler15585.2%
Electric (storage heaters, panels, boiler)179.3%
LPG63.3%
Oil31.6%
Solid fuel (wood, coal)10.5%
Loft / roof insulationHomesShare
No insulation3820.9%
Under 200 mm6937.9%
200 mm or more3720.3%
Insulated (depth not recorded)2513.7%
Flat or other home above116.0%
Other21.1%
WindowsHomesShare
Double glazed12568.7%
Single glazed3016.5%
Secondary glazing2714.8%

Energy rating: B 2 (1.1%) · C 18 (9.9%) · D 89 (48.9%) · E 54 (29.7%) · F 16 (8.8%) · G 3 (1.6%). Houses and bungalows: 88% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 September 1969.

Compared with Rother and England

Share of homesWinchelseaAll 10 areas in RotherEngland
Solid walls, no insulation40.1%49.5%48.7%
Gas boiler85.2%72.2%66.4%
Rated D–G89.0%—56.5%

Caveats

All conservation areas in Rother · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker