EPC Price Check

Solar panels, heat pumps and insulation in Battle conservation area

In the Battle conservation area (Rother), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 107 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 239 homes inside the boundary have an energy certificate: 39.7% are solid-wall homes with no wall insulation, 76.2% heat with a gas boiler and 65.3% are rated D–G; 2 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

239homes with an energy certificate
39.7%solid walls, no insulation
76.2%heated by a gas boiler
2heat pumps

Article 4: Rother publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Battle

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 239)

WallsHomesShare
Solid wall (brick or stone), no insulation9539.7%
Cavity wall, insulated (as built or unspecified)4920.5%
Timber frame3012.6%
Cavity wall, unfilled2410.0%
Modern wall (U-value from the design)218.8%
Cavity wall, filled72.9%
Solid wall, internal insulation62.5%
Cavity wall, partly insulated31.3%
Solid wall, insulated31.3%
Cavity wall, internal or external insulation10.4%
HeatingHomesShare
Gas boiler18276.2%
Electric (storage heaters, panels, boiler)5221.8%
Heat pump20.8%
Solid fuel (wood, coal)20.8%
Oil10.4%
Loft / roof insulationHomesShare
No insulation4719.7%
Under 200 mm5020.9%
200 mm or more5523.0%
Insulated (depth not recorded)3514.6%
Flat or other home above3313.8%
Other197.9%
WindowsHomesShare
Double glazed16267.8%
Single glazed5422.6%
Secondary glazing239.6%

Energy rating: A 2 (0.8%) · B 12 (5.0%) · C 69 (28.9%) · D 84 (35.1%) · E 60 (25.1%) · F 9 (3.8%) · G 3 (1.3%). Houses and bungalows: 58% of the homes; solar panels on 0.4% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 June 1971.

Compared with Rother and England

Share of homesBattleAll 10 areas in RotherEngland
Solid walls, no insulation39.7%49.5%48.7%
Gas boiler76.2%72.2%66.4%
Rated D–G65.3%—56.5%

Caveats

All conservation areas in Rother · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker