EPC Price Check

Solar panels, heat pumps and insulation in Haslingden conservation area

In the Haslingden conservation area (Rossendale), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Rossendale covers this area but deals with other things (such as changes of use); it does not change the rules below. The area has 10 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 587 homes inside the boundary have an energy certificate: 78.2% are solid-wall homes with no wall insulation, 88.8% heat with a gas boiler and 82.5% are rated D–G; 2 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

587homes with an energy certificate
78.2%solid walls, no insulation
88.8%heated by a gas boiler
2heat pumps

Article 4: An Article 4 direction published by Rossendale covers this area but deals with other things (such as changes of use); it does not change the rules below. (Immediate Article 4 Direction for small Houses in Multiple Occupation)

What needs planning permission in Haslingden

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 587)

WallsHomesShare
Solid wall (brick or stone), no insulation45978.2%
Solid wall, internal insulation406.8%
Cavity wall, filled376.3%
Cavity wall, unfilled284.8%
Modern wall (U-value from the design)81.4%
Cavity wall, insulated (as built or unspecified)50.9%
Solid wall, insulated50.9%
Timber frame20.3%
Cavity wall, internal or external insulation10.2%
Cavity wall, partly insulated10.2%
Solid wall, partly insulated10.2%
HeatingHomesShare
Gas boiler52188.8%
Electric (storage heaters, panels, boiler)569.5%
Communal heating71.2%
Heat pump20.3%
Solid fuel (wood, coal)10.2%
Loft / roof insulationHomesShare
No insulation24641.9%
Under 200 mm8614.7%
200 mm or more14524.7%
Insulated (depth not recorded)5910.1%
Flat or other home above467.8%
Other50.9%
WindowsHomesShare
Double glazed56996.9%
Single glazed162.7%
Secondary glazing10.2%
Triple glazed10.2%

Energy rating: B 4 (0.7%) · C 99 (16.9%) · D 262 (44.6%) · E 186 (31.7%) · F 29 (4.9%) · G 7 (1.2%). Houses and bungalows: 77% of the homes; solar panels on 0.2% of the certificates. Most common build period on the certificates: before 1900. Designated: 4 July 2018.

Compared with Rossendale and England

Share of homesHaslingdenAll 11 areas in RossendaleEngland
Solid walls, no insulation78.2%69.6%48.7%
Gas boiler88.8%78.7%66.4%
Rated D–G82.5%—56.5%

Caveats

All conservation areas in Rossendale · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker