EPC Price Check

Solar panels, heat pumps and insulation in Broad Street conservation area

In the Broad Street conservation area (Richmond upon Thames), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. 87 homes inside the boundary have an energy certificate: 59% are solid-wall homes with no wall insulation, 75% heat with a gas boiler and 62% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

87homes with an energy certificate
59%solid walls, no insulation
75%heated by a gas boiler
0heat pumps

Article 4: Richmond upon Thames does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Broad Street

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 87)

WallsHomesShare
Solid wall (brick or stone), no insulation5159%
Cavity wall, insulated (as built or unspecified)1821%
Timber frame78%
Cavity wall, partly insulated56%
Modern wall (U-value from the design)33%
Solid wall, insulated11%
Solid wall, internal insulation11%
Solid wall, partly insulated11%
HeatingHomesShare
Gas boiler6575%
Electric (storage heaters, panels, boiler)2225%
Loft / roof insulationHomesShare
No insulation1821%
Under 200 mm67%
200 mm or more45%
Insulated (depth not recorded)1517%
Flat or other home above4248%
Other22%
WindowsHomesShare
Double glazed6979%
Single glazed1214%
Secondary glazing45%
Triple glazed22%

Energy rating: B 3 (3%) · C 30 (34%) · D 39 (45%) · E 14 (16%) · G 1 (1%). Houses and bungalows: 1% of the homes; solar panels on 0% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 20 February 2019.

Compared with Richmond upon Thames and England

Share of homesBroad StreetAll 85 areas in Richmond upon ThamesEngland
Solid walls, no insulation59%63.5%48.7%
Gas boiler75%83.6%66.4%
Rated D–G62%—56.5%

Caveats

All conservation areas in Richmond upon Thames · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker