Solar panels, heat pumps and insulation in Castor conservation area

In the Castor conservation area (Peterborough), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 60 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 101 homes inside the boundary have an energy certificate: 39.6% are solid-wall homes with no wall insulation, 70.3% heat with a gas boiler and 71.3% are rated D–G; 2 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

101homes with an energy certificate
39.6%solid walls, no insulation
70.3%heated by a gas boiler
2heat pumps

Article 4: Peterborough publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Castor

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 101)

WallsHomesShare
Solid wall (brick or stone), no insulation4039.6%
Cavity wall, filled2524.8%
Cavity wall, insulated (as built or unspecified)2221.8%
Cavity wall, unfilled44.0%
Solid wall, insulated33.0%
Modern wall (U-value from the design)22.0%
Timber frame22.0%
Cavity wall, internal or external insulation11.0%
Cavity wall, partly insulated11.0%
Solid wall, internal insulation11.0%
HeatingHomesShare
Gas boiler7170.3%
Oil2120.8%
Electric (storage heaters, panels, boiler)65.9%
Heat pump22.0%
LPG11.0%
Loft / roof insulationHomesShare
No insulation1110.9%
Under 200 mm2423.8%
200 mm or more4241.6%
Insulated (depth not recorded)1918.8%
Other55.0%
WindowsHomesShare
Double glazed7978.2%
Single glazed1817.8%
Secondary glazing44.0%

Energy rating: B 4 (4.0%) · C 25 (24.8%) · D 40 (39.6%) · E 26 (25.7%) · F 5 (5.0%) · G 1 (1.0%). Houses and bungalows: 100% of the homes; solar panels on 1.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 26 August 1969.

Compared with Peterborough and England

Share of homesCastorAll 29 areas in PeterboroughEngland
Solid walls, no insulation39.6%40.0%48.7%
Gas boiler70.3%59.8%66.4%
Rated D–G71.3%—56.5%