EPC Price Check

Solar panels, heat pumps and insulation in Calver conservation area

In the Calver conservation area (Peak District National Park Authority), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 7 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 100 homes inside the boundary have an energy certificate: 49.0% are solid-wall homes with no wall insulation, 92.0% heat with a gas boiler and 58.0% are rated D–G; 5 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

100homes with an energy certificate
49.0%solid walls, no insulation
92.0%heated by a gas boiler
5heat pumps

Article 4: Peak District National Park Authority publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Calver

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 100)

WallsHomesShare
Solid wall (brick or stone), no insulation4949.0%
Solid wall, insulated2121.0%
Cavity wall, insulated (as built or unspecified)1919.0%
Solid wall, internal insulation55.0%
Modern wall (U-value from the design)44.0%
Cavity wall, unfilled22.0%
HeatingHomesShare
Gas boiler9292.0%
Heat pump55.0%
Electric (storage heaters, panels, boiler)22.0%
Solid fuel (wood, coal)11.0%
Loft / roof insulationHomesShare
No insulation1212.0%
Under 200 mm1818.0%
200 mm or more2828.0%
Insulated (depth not recorded)2525.0%
Flat or other home above1313.0%
Other44.0%
WindowsHomesShare
Double glazed7979.0%
Single glazed1212.0%
Secondary glazing99.0%

Energy rating: B 3 (3.0%) · C 39 (39.0%) · D 37 (37.0%) · E 16 (16.0%) · F 5 (5.0%). Houses and bungalows: 74% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 19 December 1997.

Compared with Peak District National Park Authority and England

Share of homesCalverAll 111 areas in Peak District National Park AuthorityEngland
Solid walls, no insulation49.0%72.6%48.7%
Gas boiler92.0%63.8%66.4%
Rated D–G58.0%—56.5%

Caveats

All conservation areas in Peak District National Park Authority · The rules for every conservation area