EPC Price Check

Solar panels, heat pumps and insulation in Jericho conservation area

In the Jericho conservation area (Oxford), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Oxford covers this area and removes permitted development rights for solar panels on the house, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), painting the outside, so there these need planning permission too. The area has 6 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,130 homes inside the boundary have an energy certificate: 38.4% are solid-wall homes with no wall insulation, 66.2% heat with a gas boiler and 42.2% are rated D–G; 16 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,130homes with an energy certificate
38.4%solid walls, no insulation
66.2%heated by a gas boiler
16heat pumps

Article 4: An Article 4 direction published by Oxford covers this area and removes permitted development rights for solar panels on the house, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), painting the outside, so there these need planning permission too. (Houses in Multiple Occupation Article 4 Direction; The Jericho Article 4 Direction)

What needs planning permission in Jericho

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)Planning permission needed (an Article 4 direction here removes this right)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Planning permission needed (an Article 4 direction here removes this right)Part 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,130)

WallsHomesShare
Solid wall (brick or stone), no insulation43438.4%
Cavity wall, insulated (as built or unspecified)27524.3%
Cavity wall, filled1119.8%
Modern wall (U-value from the design)1099.6%
Cavity wall, unfilled918.1%
Cavity wall, partly insulated292.6%
Solid wall, internal insulation232.0%
Other or not known191.7%
Timber frame181.6%
Cavity wall, internal or external insulation131.2%
Solid wall, external insulation50.4%
Solid wall, insulated20.2%
Solid wall, partly insulated10.1%
HeatingHomesShare
Gas boiler74866.2%
Electric (storage heaters, panels, boiler)36432.2%
Heat pump161.4%
Communal heating10.1%
Solid fuel (wood, coal)10.1%
Loft / roof insulationHomesShare
No insulation13411.9%
Under 200 mm19417.2%
200 mm or more17415.4%
Insulated (depth not recorded)16414.5%
Flat or other home above39234.7%
Other726.4%
WindowsHomesShare
Double glazed1,02490.6%
Single glazed797.0%
Secondary glazing201.8%
Triple glazed70.6%

Energy rating: A 9 (0.8%) · B 102 (9.0%) · C 542 (48.0%) · D 347 (30.7%) · E 115 (10.2%) · F 11 (1.0%) · G 4 (0.4%). Houses and bungalows: 48% of the homes; solar panels on 0.6% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 23 February 2011.

Compared with Oxford and England

Share of homesJerichoAll 18 areas in OxfordEngland
Solid walls, no insulation38.4%41.0%48.7%
Gas boiler66.2%69.7%66.4%
Rated D–G42.2%—56.5%

Caveats

All conservation areas in Oxford · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker