EPC Price Check

Solar panels, heat pumps and insulation in Gilling West conservation area

In the Gilling West conservation area (North Yorkshire), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 61 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 116 homes inside the boundary have an energy certificate: 59.5% are solid-wall homes with no wall insulation, 0.0% heat with a gas boiler and 84.5% are rated D–G; 13 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

116homes with an energy certificate
59.5%solid walls, no insulation
0.0%heated by a gas boiler
13heat pumps

Article 4: North Yorkshire does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Gilling West

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 116)

WallsHomesShare
Solid wall (brick or stone), no insulation6959.5%
Modern wall (U-value from the design)1210.3%
Cavity wall, filled108.6%
Cavity wall, unfilled86.9%
Solid wall, internal insulation76.0%
Cavity wall, insulated (as built or unspecified)65.2%
Cavity wall, partly insulated32.6%
Solid wall, insulated10.9%
HeatingHomesShare
Oil6152.6%
Electric (storage heaters, panels, boiler)3530.2%
Heat pump1311.2%
Solid fuel (wood, coal)43.4%
LPG32.6%
Loft / roof insulationHomesShare
No insulation76.0%
Under 200 mm2521.6%
200 mm or more6354.3%
Insulated (depth not recorded)97.8%
Other1210.3%
WindowsHomesShare
Double glazed7262.1%
Single glazed3832.8%
Secondary glazing65.2%

Energy rating: B 11 (9.5%) · C 7 (6.0%) · D 25 (21.6%) · E 58 (50.0%) · F 13 (11.2%) · G 2 (1.7%). Houses and bungalows: 95% of the homes; solar panels on 0.9% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 January 1979.

Compared with North Yorkshire and England

Share of homesGilling WestAll 248 areas in North YorkshireEngland
Solid walls, no insulation59.5%54.2%48.7%
Gas boiler0.0%64.9%66.4%
Rated D–G84.5%—56.5%

Caveats

All conservation areas in North Yorkshire · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker