Solar panels, heat pumps and insulation in Binham conservation area

In the Binham conservation area (North Norfolk), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by North Norfolk covers part of this area (about 15% of it), but the published data does not say which rights it removes — check the direction before any work. The area has 30 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 153 homes inside the boundary have an energy certificate: 35.3% are solid-wall homes with no wall insulation, 0.0% heat with a gas boiler and 70.6% are rated D–G; 6 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

153homes with an energy certificate
35.3%solid walls, no insulation
0.0%heated by a gas boiler
6heat pumps

Article 4: An Article 4 direction published by North Norfolk covers part of this area (about 15% of it), but the published data does not say which rights it removes — check the direction before any work. (Article 4 Direction - Land At Binham)

What needs planning permission in Binham

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 153)

WallsHomesShare
Solid wall (brick or stone), no insulation5435.3%
Modern wall (U-value from the design)2919.0%
Cavity wall, filled2818.3%
Cavity wall, insulated (as built or unspecified)1811.8%
Solid wall, insulated95.9%
Solid wall, internal insulation63.9%
Timber frame53.3%
Solid wall, partly insulated21.3%
Cavity wall, partly insulated10.7%
Cavity wall, unfilled10.7%
HeatingHomesShare
Oil6441.8%
Electric (storage heaters, panels, boiler)4730.7%
LPG3019.6%
Heat pump63.9%
Solid fuel (wood, coal)42.6%
Communal heating21.3%
Loft / roof insulationHomesShare
No insulation117.2%
Under 200 mm3422.4%
200 mm or more4328.3%
Insulated (depth not recorded)3019.7%
Flat or other home above53.3%
Other2919.1%
WindowsHomesShare
Double glazed13688.9%
Single glazed95.9%
Secondary glazing85.2%

Energy rating: B 3 (2.0%) · C 42 (27.5%) · D 39 (25.5%) · E 44 (28.8%) · F 20 (13.1%) · G 5 (3.3%). Houses and bungalows: 95% of the homes; solar panels on 1.3% of the certificates. Most common build period on the certificates: before 1900. Designated: 31 December 1974.

Compared with North Norfolk and England

Share of homesBinhamAll 91 areas in North NorfolkEngland
Solid walls, no insulation35.3%50.6%48.7%
Gas boiler0.0%40.3%66.4%
Rated D–G70.6%—56.5%

Caveats

All conservation areas in North Norfolk · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker