EPC Price Check

Solar panels, heat pumps and insulation in Madeley conservation area

In the Madeley conservation area (Newcastle-under-Lyme), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Newcastle-under-Lyme covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), so there these need planning permission too. The area has 21 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 160 homes inside the boundary have an energy certificate: 26.2% are solid-wall homes with no wall insulation, 93.8% heat with a gas boiler and 55.6% are rated D–G; 1 has a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

160homes with an energy certificate
26.2%solid walls, no insulation
93.8%heated by a gas boiler
1heat pumps

Article 4: An Article 4 direction published by Newcastle-under-Lyme covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), so there these need planning permission too. (Madeley)

What needs planning permission in Madeley

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 160)

WallsHomesShare
Solid wall (brick or stone), no insulation4226.2%
Cavity wall, filled3924.4%
Cavity wall, insulated (as built or unspecified)3622.5%
Modern wall (U-value from the design)148.8%
Solid wall, insulated95.6%
Cavity wall, unfilled85.0%
Solid wall, internal insulation53.1%
Cavity wall, partly insulated31.9%
Other or not known31.9%
Cavity wall, internal or external insulation10.6%
HeatingHomesShare
Gas boiler15093.8%
Oil42.5%
Electric (storage heaters, panels, boiler)21.2%
Solid fuel (wood, coal)21.2%
Heat pump10.6%
LPG10.6%
Loft / roof insulationHomesShare
No insulation1811.2%
Under 200 mm4830.0%
200 mm or more5232.5%
Insulated (depth not recorded)2616.2%
Flat or other home above21.2%
Other148.8%
WindowsHomesShare
Double glazed15999.4%
Single glazed10.6%

Energy rating: B 12 (7.5%) · C 59 (36.9%) · D 62 (38.8%) · E 23 (14.4%) · F 2 (1.2%) · G 2 (1.2%). Houses and bungalows: 96% of the homes; solar panels on 0.6% of the certificates. Most common build period on the certificates: before 1900. Designated: 25 January 1974.

Compared with Newcastle-under-Lyme and England

Share of homesMadeleyAll 22 areas in Newcastle-under-LymeEngland
Solid walls, no insulation26.2%29.9%48.7%
Gas boiler93.8%59.0%66.4%
Rated D–G55.6%—56.5%

Caveats

All conservation areas in Newcastle-under-Lyme · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker