Solar panels, heat pumps and insulation in Martin conservation area

In the Martin conservation area (New Forest), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 38 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 48 homes inside the boundary have an energy certificate: 48% are solid-wall homes with no wall insulation, 0% heat with a gas boiler and 88% are rated D–G; 8 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

48homes with an energy certificate
48%solid walls, no insulation
0%heated by a gas boiler
8heat pumps

Article 4: New Forest publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Martin

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 48)

WallsHomesShare
Solid wall (brick or stone), no insulation2348%
Cavity wall, filled1225%
Cavity wall, unfilled612%
Cavity wall, insulated (as built or unspecified)24%
Solid wall, internal insulation24%
Modern wall (U-value from the design)12%
Other or not known12%
Solid wall, insulated12%
HeatingHomesShare
Oil2960%
Heat pump817%
LPG510%
Electric (storage heaters, panels, boiler)36%
Solid fuel (wood, coal)36%
Loft / roof insulationHomesShare
Under 200 mm1430%
200 mm or more1634%
Insulated (depth not recorded)1226%
Other511%
WindowsHomesShare
Double glazed4083%
Single glazed48%
Secondary glazing36%
Triple glazed12%

Energy rating: B 1 (2%) · C 5 (10%) · D 14 (29%) · E 22 (46%) · F 4 (8%) · G 2 (4%). Houses and bungalows: 98% of the homes; solar panels on 2% of the certificates. Most common build period on the certificates: before 1900. Designated: 2 February 2000.

Compared with New Forest and England

Share of homesMartinAll 22 areas in New ForestEngland
Solid walls, no insulation48%21.3%48.7%
Gas boiler0%53.4%66.4%
Rated D–G88%—56.5%

Caveats

All conservation areas in New Forest · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker