EPC Price Check

Solar panels, heat pumps and insulation in Hurstpierpoint conservation area

In the Hurstpierpoint conservation area (Mid Sussex), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 42 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 475 homes inside the boundary have an energy certificate: 36.4% are solid-wall homes with no wall insulation, 83.2% heat with a gas boiler and 73.1% are rated D–G; 3 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

475homes with an energy certificate
36.4%solid walls, no insulation
83.2%heated by a gas boiler
3heat pumps

Article 4: Mid Sussex does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Hurstpierpoint

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 475)

WallsHomesShare
Solid wall (brick or stone), no insulation17336.4%
Cavity wall, unfilled11023.2%
Cavity wall, insulated (as built or unspecified)6513.7%
Cavity wall, filled4810.1%
Modern wall (U-value from the design)347.2%
Solid wall, internal insulation132.7%
Timber frame112.3%
Solid wall, insulated102.1%
Cavity wall, partly insulated61.3%
Cavity wall, internal or external insulation51.1%
HeatingHomesShare
Gas boiler39583.2%
Electric (storage heaters, panels, boiler)7315.4%
Heat pump30.6%
Communal heating20.4%
LPG10.2%
Solid fuel (wood, coal)10.2%
Loft / roof insulationHomesShare
No insulation7415.6%
Under 200 mm13428.2%
200 mm or more8517.9%
Insulated (depth not recorded)8517.9%
Flat or other home above6513.7%
Other326.7%
WindowsHomesShare
Double glazed37679.2%
Single glazed7415.6%
Secondary glazing255.3%

Energy rating: A 1 (0.2%) · B 9 (1.9%) · C 118 (24.8%) · D 244 (51.4%) · E 81 (17.1%) · F 22 (4.6%). Houses and bungalows: 65% of the homes; solar panels on 0.6% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 1 January 1999.

Compared with Mid Sussex and England

Share of homesHurstpierpointAll 35 areas in Mid SussexEngland
Solid walls, no insulation36.4%25.2%48.7%
Gas boiler83.2%77.3%66.4%
Rated D–G73.1%—56.5%

Caveats

All conservation areas in Mid Sussex · The rules for every conservation area