EPC Price Check

Solar panels, heat pumps and insulation in Rainham conservation area

In the Rainham conservation area (Medway), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 12 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 145 homes inside the boundary have an energy certificate: 22.8% are solid-wall homes with no wall insulation, 36.6% heat with a gas boiler and 33.1% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

145homes with an energy certificate
22.8%solid walls, no insulation
36.6%heated by a gas boiler
0heat pumps

Article 4: Medway publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Rainham

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 145)

WallsHomesShare
Solid wall (brick or stone), no insulation3322.8%
Cavity wall, filled2819.3%
Cavity wall, insulated (as built or unspecified)2517.2%
Cavity wall, partly insulated2315.9%
Cavity wall, unfilled117.6%
Modern wall (U-value from the design)74.8%
Solid wall, insulated74.8%
Timber frame74.8%
Solid wall, internal insulation42.8%
HeatingHomesShare
Communal heating6746.2%
Gas boiler5336.6%
Electric (storage heaters, panels, boiler)2517.2%
Loft / roof insulationHomesShare
No insulation117.6%
Under 200 mm2013.8%
200 mm or more1611.0%
Insulated (depth not recorded)3624.8%
Flat or other home above5840.0%
Other42.8%
WindowsHomesShare
Double glazed13291.0%
Single glazed106.9%
Secondary glazing32.1%

Energy rating: B 1 (0.7%) · C 96 (66.2%) · D 29 (20.0%) · E 14 (9.7%) · F 3 (2.1%) · G 2 (1.4%). Houses and bungalows: 12% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1976-1982. Designated: 11 January 1977.

Compared with Medway and England

Share of homesRainhamAll 24 areas in MedwayEngland
Solid walls, no insulation22.8%35.9%48.7%
Gas boiler36.6%69.7%66.4%
Rated D–G33.1%—56.5%

Caveats

All conservation areas in Medway · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker