Solar panels, heat pumps and insulation in Chancery Lane conservation area
In the Chancery Lane conservation area (London Corporation), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 21 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 294 homes inside the boundary have an energy certificate: 23.5% are solid-wall homes with no wall insulation, 2.0% heat with a gas boiler and 35.7% are rated D–G; 10 have a heat pump. EPC register November 2026; rules as at 21 October 2026.
Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources
294homes with an energy certificate
23.5%solid walls, no insulation
2.0%heated by a gas boiler
10heat pumps
Article 4: London Corporation does not publish Article 4 areas on planning.data.gov.uk — check with the council.
What needs planning permission in Chancery Lane
Work (house, not listed)
In a conservation area
Rule
Air source heat pump on a wall or roof facing the road, or nearer the road than the house
Planning permission needed
Part 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)
No permission needed (permitted development), unless an Article 4 direction removes it — check with the council
Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)
No permission needed (permitted development), unless an Article 4 direction removes it — check with the council
Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the road
Planning permission needed
Part 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)
Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the council
Replacement windows and doors of similar appearance
No permission needed (permitted development), unless an Article 4 direction removes it — check with the council
Part 1 Class A, A.3(a)
Listed buildings: 21 in the area (grade I: 2, II*: 6). The table is for houses that are not listed: on a listed building, solar panels and air source heat pumps are not permitted development at all (they need planning permission), and any of these works needs listed building consent.
Flats: 100% of the certified homes here are flats or maisonettes. Homes in a block of flats have no householder rights for alterations; heat pumps and solar have their own, tighter rules for blocks of flats.
The homes in the area (latest certificate per home, n = 294)
Walls
Homes
Share
Other or not known
77
26.2%
Solid wall (brick or stone), no insulation
69
23.5%
Modern wall (U-value from the design)
65
22.1%
Cavity wall, insulated (as built or unspecified)
34
11.6%
Solid wall, insulated
13
4.4%
Timber frame
13
4.4%
Solid wall, internal insulation
12
4.1%
Cavity wall, unfilled
5
1.7%
Cavity wall, partly insulated
3
1.0%
Cavity wall, filled
1
0.3%
Solid wall, external insulation
1
0.3%
Solid wall, partly insulated
1
0.3%
Heating
Homes
Share
Electric (storage heaters, panels, boiler)
153
52.0%
Communal heating
125
42.5%
Heat pump
10
3.4%
Gas boiler
6
2.0%
Loft / roof insulation
Homes
Share
No insulation
16
5.4%
Under 200 mm
1
0.3%
200 mm or more
1
0.3%
Insulated (depth not recorded)
14
4.8%
Flat or other home above
234
79.6%
Other
28
9.5%
Windows
Homes
Share
Double glazed
263
89.5%
Single glazed
20
6.8%
Secondary glazing
9
3.1%
Triple glazed
2
0.7%
BCDE
Energy rating: B 86 (29.3%) · C 103 (35.0%) · D 63 (21.4%) · E 38 (12.9%) · F 3 (1.0%) · G 1 (0.3%). Houses and bungalows: 0% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1930-1949. Designated: 22 September 2007.
Compared with London Corporation and England
Share of homes
Chancery Lane
All 28 areas in London Corporation
England
Solid walls, no insulation
23.5%
25.6%
48.7%
Gas boiler
2.0%
21.6%
66.4%
Rated D–G
35.7%
—
56.5%
Caveats
Certificates describe a home when it was assessed; 59% of these are from 2020 or later (latest 21 October 2026). “No insulation (assumed)” is the assessor's default for older walls.
The rules are England's national permitted development rules (General Permitted Development Order 2015, Schedule 2, as at 21 October 2026). They do not cover building regulations or a council's own conditions. This is not a planning decision: ask London Corporation if in doubt.
Boundary: City of London Corporation via planning.data.gov.uk (entity 44002506, reference 26, 6.6 ha); the council's appraisal or map. Homes are placed by the coordinates of their UPRN (OS Open UPRN); addresses are not shown.