Solar panels, heat pumps and insulation in Newenham Crescent conservation area

In the Newenham Crescent conservation area (Liverpool), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. 110 homes inside the boundary have an energy certificate: 0.9% are solid-wall homes with no wall insulation, 96.4% heat with a gas boiler and 52.7% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

110homes with an energy certificate
0.9%solid walls, no insulation
96.4%heated by a gas boiler
0heat pumps

Article 4: Liverpool publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Newenham Crescent

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 110)

WallsHomesShare
Cavity wall, filled8476.4%
Cavity wall, unfilled2320.9%
Cavity wall, insulated (as built or unspecified)10.9%
Solid wall (brick or stone), no insulation10.9%
Solid wall, insulated10.9%
HeatingHomesShare
Gas boiler10696.4%
Electric (storage heaters, panels, boiler)32.7%
Communal heating10.9%
Loft / roof insulationHomesShare
No insulation1816.4%
Under 200 mm3430.9%
200 mm or more5247.3%
Insulated (depth not recorded)65.5%
WindowsHomesShare
Double glazed10797.3%
Single glazed21.8%
Triple glazed10.9%

Energy rating: B 7 (6.4%) · C 45 (40.9%) · D 41 (37.3%) · E 11 (10.0%) · F 4 (3.6%) · G 2 (1.8%). Houses and bungalows: 100% of the homes; solar panels on 3.6% of the certificates. Most common build period on the certificates: 1930-1949. Designated: 24 April 1996.

Compared with Liverpool and England

Share of homesNewenham CrescentAll 37 areas in LiverpoolEngland
Solid walls, no insulation0.9%41.6%48.7%
Gas boiler96.4%53.3%66.4%
Rated D–G52.7%—56.5%

Caveats

All conservation areas in Liverpool · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker