Solar panels, heat pumps and insulation in St Marys conservation area

In the St Marys conservation area (Lewisham), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Lewisham covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), painting the outside, so there these need planning permission too. The area has 10 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 183 homes inside the boundary have an energy certificate: 47.5% are solid-wall homes with no wall insulation, 57.9% heat with a gas boiler and 41.5% are rated D–G; 32 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

183homes with an energy certificate
47.5%solid walls, no insulation
57.9%heated by a gas boiler
32heat pumps

Article 4: An Article 4 direction published by Lewisham covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), painting the outside, so there these need planning permission too. (Lewisham Major Centre; Small HMO Northern Extension; St Mary's Conservation Area Article 4 Direction)

What needs planning permission in St Marys

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 183)

WallsHomesShare
Solid wall (brick or stone), no insulation8747.5%
Modern wall (U-value from the design)3318.0%
Other or not known2714.8%
Cavity wall, insulated (as built or unspecified)147.7%
Solid wall, internal insulation105.5%
Solid wall, insulated63.3%
Timber frame52.7%
Cavity wall, unfilled10.5%
HeatingHomesShare
Gas boiler10657.9%
Electric (storage heaters, panels, boiler)3720.2%
Heat pump3217.5%
Communal heating84.4%
Loft / roof insulationHomesShare
No insulation3720.2%
Under 200 mm168.7%
200 mm or more42.2%
Insulated (depth not recorded)179.3%
Flat or other home above8747.5%
Other2212.0%
WindowsHomesShare
Double glazed15685.2%
Single glazed158.2%
Secondary glazing126.6%

Energy rating: B 36 (19.7%) · C 71 (38.8%) · D 56 (30.6%) · E 19 (10.4%) · F 1 (0.5%). Houses and bungalows: 13% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 1 January 1976.

Compared with Lewisham and England

Share of homesSt MarysAll 31 areas in LewishamEngland
Solid walls, no insulation47.5%69.0%48.7%
Gas boiler57.9%85.5%66.4%
Rated D–G41.5%—56.5%