EPC Price Check

Solar panels, heat pumps and insulation in Greyfriars conservation area

In the Greyfriars conservation area (Leicester), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 38 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 252 homes inside the boundary have an energy certificate: 27.0% are solid-wall homes with no wall insulation, 37.7% heat with a gas boiler and 46.4% are rated D–G; 26 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

252homes with an energy certificate
27.0%solid walls, no insulation
37.7%heated by a gas boiler
26heat pumps

Article 4: Leicester publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Greyfriars

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 252)

WallsHomesShare
Modern wall (U-value from the design)7128.2%
Solid wall (brick or stone), no insulation6827.0%
Cavity wall, insulated (as built or unspecified)4116.3%
Solid wall, internal insulation3714.7%
Solid wall, insulated166.3%
Other or not known83.2%
Cavity wall, unfilled52.0%
Timber frame41.6%
Cavity wall, internal or external insulation10.4%
Solid wall, partly insulated10.4%
HeatingHomesShare
Electric (storage heaters, panels, boiler)11344.8%
Gas boiler9537.7%
Heat pump2610.3%
Communal heating187.1%
Loft / roof insulationHomesShare
No insulation207.9%
Under 200 mm114.4%
200 mm or more156.0%
Insulated (depth not recorded)218.3%
Flat or other home above14657.9%
Other3915.5%
WindowsHomesShare
Double glazed18673.8%
Single glazed3714.7%
Secondary glazing2911.5%

Energy rating: B 45 (17.9%) · C 90 (35.7%) · D 76 (30.2%) · E 38 (15.1%) · F 3 (1.2%). Houses and bungalows: 12% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 6 December 2014.

Compared with Leicester and England

Share of homesGreyfriarsAll 25 areas in LeicesterEngland
Solid walls, no insulation27.0%43.4%48.7%
Gas boiler37.7%45.7%66.4%
Rated D–G46.4%—56.5%

Caveats

All conservation areas in Leicester · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker