EPC Price Check

Solar panels, heat pumps and insulation in Turnham Green conservation area

In the Turnham Green conservation area (Hounslow), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Hounslow covers this area but deals with other things (such as changes of use); it does not change the rules below. The area has 19 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,371 homes inside the boundary have an energy certificate: 65.2% are solid-wall homes with no wall insulation, 54.2% heat with a gas boiler and 57.0% are rated D–G; 23 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,371homes with an energy certificate
65.2%solid walls, no insulation
54.2%heated by a gas boiler
23heat pumps

Article 4: An Article 4 direction published by Hounslow covers this area but deals with other things (such as changes of use); it does not change the rules below. (Change of use or development that would result in new dwellings (Class MA/ZA); Dwellinghouses (C3) to small HMOs (C4) - borough-wide Article 4 Direction)

What needs planning permission in Turnham Green

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,371)

WallsHomesShare
Solid wall (brick or stone), no insulation89465.2%
Modern wall (U-value from the design)20214.7%
Cavity wall, insulated (as built or unspecified)856.2%
Cavity wall, unfilled614.4%
Timber frame503.6%
Solid wall, internal insulation181.3%
Solid wall, insulated171.2%
Cavity wall, partly insulated151.1%
Other or not known120.9%
Cavity wall, filled100.7%
Solid wall, partly insulated60.4%
Cavity wall, internal or external insulation10.1%
HeatingHomesShare
Gas boiler74354.2%
Communal heating45032.8%
Electric (storage heaters, panels, boiler)15111.0%
Heat pump231.7%
LPG20.1%
Oil10.1%
Solid fuel (wood, coal)10.1%
Loft / roof insulationHomesShare
No insulation24718.0%
Under 200 mm936.8%
200 mm or more473.4%
Insulated (depth not recorded)15811.5%
Flat or other home above74354.2%
Other826.0%
WindowsHomesShare
Double glazed1,05977.2%
Single glazed27620.1%
Secondary glazing282.0%
Triple glazed80.6%

Energy rating: A 5 (0.4%) · B 127 (9.3%) · C 457 (33.3%) · D 543 (39.6%) · E 212 (15.5%) · F 19 (1.4%) · G 8 (0.6%). Houses and bungalows: 21% of the homes; solar panels on 0.1% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 4 September 1975.

Compared with Hounslow and England

Share of homesTurnham GreenAll 29 areas in HounslowEngland
Solid walls, no insulation65.2%49.9%48.7%
Gas boiler54.2%77.4%66.4%
Rated D–G57.0%—56.5%

Caveats

All conservation areas in Hounslow · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker