EPC Price Check

Solar panels, heat pumps and insulation in Hillingdon Village conservation area

In the Hillingdon Village conservation area (Hillingdon), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Hillingdon covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, so there these need planning permission too. The area has 15 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 125 homes inside the boundary have an energy certificate: 20.8% are solid-wall homes with no wall insulation, 94.4% heat with a gas boiler and 48.0% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

125homes with an energy certificate
20.8%solid walls, no insulation
94.4%heated by a gas boiler
0heat pumps

Article 4: An Article 4 direction published by Hillingdon covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, so there these need planning permission too. (Changes of use from commercial, business and service uses to dwellinghouses; Houses of Multiple Occupation (HMOs); Residential extensions)

What needs planning permission in Hillingdon Village

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 125)

WallsHomesShare
Cavity wall, insulated (as built or unspecified)3024.0%
Solid wall (brick or stone), no insulation2620.8%
Cavity wall, filled2116.8%
Cavity wall, partly insulated1713.6%
Cavity wall, unfilled1512.0%
Modern wall (U-value from the design)86.4%
Timber frame54.0%
Cavity wall, internal or external insulation10.8%
Other or not known10.8%
Solid wall, internal insulation10.8%
HeatingHomesShare
Gas boiler11894.4%
Electric (storage heaters, panels, boiler)64.8%
LPG10.8%
Loft / roof insulationHomesShare
No insulation75.6%
Under 200 mm4636.8%
200 mm or more1814.4%
Insulated (depth not recorded)2318.4%
Flat or other home above2520.0%
Other64.8%
WindowsHomesShare
Double glazed11592.0%
Single glazed64.8%
Secondary glazing21.6%
Triple glazed21.6%

Energy rating: B 3 (2.4%) · C 62 (49.6%) · D 50 (40.0%) · E 9 (7.2%) · F 1 (0.8%). Houses and bungalows: 46% of the homes; solar panels on 0.8% of the certificates. Most common build period on the certificates: 1983-1990. Designated: 15 March 1973.

Compared with Hillingdon and England

Share of homesHillingdon VillageAll 32 areas in HillingdonEngland
Solid walls, no insulation20.8%25.5%48.7%
Gas boiler94.4%62.7%66.4%
Rated D–G48.0%—56.5%

Caveats

All conservation areas in Hillingdon · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker