Solar panels, heat pumps and insulation in Langstone conservation area
In the Langstone conservation area (Havant), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Havant covers this area and removes permitted development rights for solar panels on the house, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. The area has 7 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 58 homes inside the boundary have an energy certificate: 19% are solid-wall homes with no wall insulation, 98% heat with a gas boiler and 69% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.
Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources
58homes with an energy certificate
19%solid walls, no insulation
98%heated by a gas boiler
0heat pumps
Article 4: An Article 4 direction published by Havant covers this area and removes permitted development rights for solar panels on the house, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. (0164B3; Langstone)
What needs planning permission in Langstone
Work (house, not listed)
In a conservation area
Rule
Air source heat pump on a wall or roof facing the road, or nearer the road than the house
Planning permission needed
Part 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)
No permission needed (permitted development)
Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)
Planning permission needed (an Article 4 direction here removes this right)
Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the road
Planning permission needed
Part 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)
Planning permission needed (an Article 4 direction here removes this right)
Replacement windows and doors of similar appearance
Planning permission needed (an Article 4 direction here removes this right)
Part 1 Class A, A.3(a)
Listed buildings: 7 in the area. The table is for houses that are not listed: on a listed building, solar panels and air source heat pumps are not permitted development at all (they need planning permission), and any of these works needs listed building consent.
Flats: 2% of the certified homes here are flats or maisonettes. Homes in a block of flats have no householder rights for alterations; heat pumps and solar have their own, tighter rules for blocks of flats.
The homes in the area (latest certificate per home, n = 58)
Walls
Homes
Share
Cavity wall, unfilled
30
52%
Cavity wall, filled
11
19%
Solid wall (brick or stone), no insulation
11
19%
Cavity wall, insulated (as built or unspecified)
3
5%
Cavity wall, partly insulated
2
3%
Solid wall, external insulation
1
2%
Heating
Homes
Share
Gas boiler
57
98%
Electric (storage heaters, panels, boiler)
1
2%
Loft / roof insulation
Homes
Share
No insulation
8
14%
Under 200 mm
21
36%
200 mm or more
15
26%
Insulated (depth not recorded)
10
17%
Other
4
7%
Windows
Homes
Share
Double glazed
50
86%
Single glazed
7
12%
Secondary glazing
1
2%
CDE
Energy rating: C 18 (31%) · D 32 (55%) · E 8 (14%). Houses and bungalows: 98% of the homes; solar panels on 0% of the certificates. Most common build period on the certificates: before 1900. Designated: 26 March 2026.
Compared with Havant and England
Share of homes
Langstone
All 17 areas in Havant
England
Solid walls, no insulation
19%
17.6%
48.7%
Gas boiler
98%
75.9%
66.4%
Rated D–G
69%
—
56.5%
Caveats
Certificates describe a home when it was assessed; 47% of these are from 2020 or later (latest 17 September 2026). “No insulation (assumed)” is the assessor's default for older walls.
The rules are England's national permitted development rules (General Permitted Development Order 2015, Schedule 2, as at 21 October 2026). They do not cover building regulations or a council's own conditions. This is not a planning decision: ask Havant if in doubt.
Boundary: Havant Borough Council via planning.data.gov.uk (entity 44016373, reference 4-1, 7.3 ha); the council's appraisal or map. Homes are placed by the coordinates of their UPRN (OS Open UPRN); addresses are not shown.