EPC Price Check

Solar panels, heat pumps and insulation in Hillfield conservation area

In the Hillfield conservation area (Haringey), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. 257 homes inside the boundary have an energy certificate: 68.5% are solid-wall homes with no wall insulation, 72.4% heat with a gas boiler and 42.0% are rated D–G; 29 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

257homes with an energy certificate
68.5%solid walls, no insulation
72.4%heated by a gas boiler
29heat pumps

Article 4: Haringey publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Hillfield

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 257)

WallsHomesShare
Solid wall (brick or stone), no insulation17668.5%
Modern wall (U-value from the design)3011.7%
Timber frame218.2%
Cavity wall, insulated (as built or unspecified)124.7%
Solid wall, insulated72.7%
Other or not known41.6%
Solid wall, internal insulation31.2%
Solid wall, partly insulated20.8%
Cavity wall, internal or external insulation10.4%
Cavity wall, unfilled10.4%
HeatingHomesShare
Gas boiler18672.4%
Electric (storage heaters, panels, boiler)3614.0%
Heat pump2911.3%
Communal heating62.3%
Loft / roof insulationHomesShare
No insulation4116.0%
Under 200 mm187.0%
200 mm or more103.9%
Insulated (depth not recorded)3011.7%
Flat or other home above13050.8%
Other2710.5%
WindowsHomesShare
Double glazed20278.6%
Single glazed4718.3%
Secondary glazing72.7%
Triple glazed10.4%

Energy rating: A 4 (1.6%) · B 29 (11.3%) · C 116 (45.1%) · D 75 (29.2%) · E 25 (9.7%) · F 8 (3.1%). Houses and bungalows: 19% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 29 November 1994.

Compared with Haringey and England

Share of homesHillfieldAll 38 areas in HaringeyEngland
Solid walls, no insulation68.5%66.4%48.7%
Gas boiler72.4%80.1%66.4%
Rated D–G42.0%—56.5%

Caveats

All conservation areas in Haringey · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker