EPC Price Check

Solar panels, heat pumps and insulation in Moore Park conservation area

In the Moore Park conservation area (Hammersmith & Fulham), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 1 listed building; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,009 homes inside the boundary have an energy certificate: 51.4% are solid-wall homes with no wall insulation, 62.7% heat with a gas boiler and 50.1% are rated D–G; 30 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,009homes with an energy certificate
51.4%solid walls, no insulation
62.7%heated by a gas boiler
30heat pumps

Article 4: Hammersmith & Fulham does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Moore Park

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,009)

WallsHomesShare
Solid wall (brick or stone), no insulation51951.4%
Cavity wall, unfilled14914.8%
Cavity wall, insulated (as built or unspecified)12212.1%
Other or not known676.6%
Modern wall (U-value from the design)626.1%
Cavity wall, partly insulated303.0%
Solid wall, insulated161.6%
Solid wall, internal insulation141.4%
Timber frame141.4%
Cavity wall, filled111.1%
Cavity wall, internal or external insulation20.2%
Solid wall, partly insulated20.2%
Solid wall, external insulation10.1%
HeatingHomesShare
Gas boiler63362.7%
Electric (storage heaters, panels, boiler)20019.8%
Communal heating14614.5%
Heat pump303.0%
Loft / roof insulationHomesShare
No insulation19719.5%
Under 200 mm505.0%
200 mm or more262.6%
Insulated (depth not recorded)22422.2%
Flat or other home above47246.8%
Other404.0%
WindowsHomesShare
Double glazed87386.5%
Single glazed11010.9%
Secondary glazing252.5%
Triple glazed10.1%

Energy rating: B 68 (6.7%) · C 435 (43.1%) · D 374 (37.1%) · E 107 (10.6%) · F 22 (2.2%) · G 3 (0.3%). Houses and bungalows: 25% of the homes; solar panels on 0.1% of the certificates. Most common build period on the certificates: 1900-1929.

Compared with Hammersmith & Fulham and England

Share of homesMoore ParkAll 46 areas in Hammersmith & FulhamEngland
Solid walls, no insulation51.4%65.3%48.7%
Gas boiler62.7%70.7%66.4%
Rated D–G50.1%—56.5%

Caveats

All conservation areas in Hammersmith & Fulham · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker