Solar panels, heat pumps and insulation in Hammersmith Town Hall conservation area
In the Hammersmith Town Hall conservation area (Hammersmith & Fulham), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 6 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 585 homes inside the boundary have an energy certificate: 58.1% are solid-wall homes with no wall insulation, 74.2% heat with a gas boiler and 32.3% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.
Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources
585homes with an energy certificate
58.1%solid walls, no insulation
74.2%heated by a gas boiler
0heat pumps
Article 4: Hammersmith & Fulham does not publish Article 4 areas on planning.data.gov.uk — check with the council.
What needs planning permission in Hammersmith Town Hall
Work (house, not listed)
In a conservation area
Rule
Air source heat pump on a wall or roof facing the road, or nearer the road than the house
Planning permission needed
Part 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)
No permission needed (permitted development), unless an Article 4 direction removes it — check with the council
Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)
No permission needed (permitted development), unless an Article 4 direction removes it — check with the council
Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the road
Planning permission needed
Part 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)
Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the council
Replacement windows and doors of similar appearance
No permission needed (permitted development), unless an Article 4 direction removes it — check with the council
Part 1 Class A, A.3(a)
Listed buildings: 6 in the area. The table is for houses that are not listed: on a listed building, solar panels and air source heat pumps are not permitted development at all (they need planning permission), and any of these works needs listed building consent.
Flats: 99% of the certified homes here are flats or maisonettes. Homes in a block of flats have no householder rights for alterations; heat pumps and solar have their own, tighter rules for blocks of flats.
The homes in the area (latest certificate per home, n = 585)
Walls
Homes
Share
Solid wall (brick or stone), no insulation
340
58.1%
Modern wall (U-value from the design)
98
16.8%
Cavity wall, insulated (as built or unspecified)
36
6.2%
Timber frame
25
4.3%
Cavity wall, unfilled
19
3.2%
Other or not known
17
2.9%
Cavity wall, partly insulated
13
2.2%
Cavity wall, internal or external insulation
12
2.1%
Solid wall, internal insulation
10
1.7%
Solid wall, insulated
6
1.0%
Solid wall, external insulation
5
0.9%
Cavity wall, filled
2
0.3%
Solid wall, partly insulated
2
0.3%
Heating
Homes
Share
Gas boiler
434
74.2%
Communal heating
93
15.9%
Electric (storage heaters, panels, boiler)
57
9.7%
LPG
1
0.2%
Loft / roof insulation
Homes
Share
No insulation
69
11.8%
Under 200 mm
27
4.6%
200 mm or more
12
2.1%
Insulated (depth not recorded)
35
6.0%
Flat or other home above
398
68.0%
Other
44
7.5%
Windows
Homes
Share
Double glazed
496
84.8%
Single glazed
77
13.2%
Secondary glazing
10
1.7%
Triple glazed
2
0.3%
BCD
Energy rating: B 70 (12.0%) · C 326 (55.7%) · D 167 (28.5%) · E 20 (3.4%) · G 2 (0.3%). Houses and bungalows: 1% of the homes; solar panels on 0.2% of the certificates. Most common build period on the certificates: 1930-1949.
Compared with Hammersmith & Fulham and England
Share of homes
Hammersmith Town Hall
All 46 areas in Hammersmith & Fulham
England
Solid walls, no insulation
58.1%
65.3%
48.7%
Gas boiler
74.2%
70.7%
66.4%
Rated D–G
32.3%
—
56.5%
Caveats
Certificates describe a home when it was assessed; 65% of these are from 2020 or later (latest 10 September 2026). “No insulation (assumed)” is the assessor's default for older walls.
The rules are England's national permitted development rules (General Permitted Development Order 2015, Schedule 2, as at 21 October 2026). They do not cover building regulations or a council's own conditions. This is not a planning decision: ask Hammersmith & Fulham if in doubt.
Boundary: London Borough of Hammersmith & Fulham via planning.data.gov.uk (entity 44012337, reference 37, 8.2 ha). Homes are placed by the coordinates of their UPRN (OS Open UPRN); addresses are not shown.