EPC Price Check

Solar panels, heat pumps and insulation in South Shoreditch conservation area

In the South Shoreditch conservation area (Hackney), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Hackney covers this area but deals with other things (such as changes of use); it does not change the rules below. The area has 54 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,266 homes inside the boundary have an energy certificate: 52.6% are solid-wall homes with no wall insulation, 71.6% heat with a gas boiler and 30.3% are rated D–G; 31 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,266homes with an energy certificate
52.6%solid walls, no insulation
71.6%heated by a gas boiler
31heat pumps

Article 4: An Article 4 direction published by Hackney covers this area but deals with other things (such as changes of use); it does not change the rules below. (A4D Non-residential to residential; Hackney Central Activity Zone; London borough of Hackney; Tech City (CAZ North))

What needs planning permission in South Shoreditch

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,266)

WallsHomesShare
Solid wall (brick or stone), no insulation66652.6%
Cavity wall, insulated (as built or unspecified)18714.8%
Other or not known18114.3%
Modern wall (U-value from the design)725.7%
Solid wall, insulated614.8%
Timber frame493.9%
Solid wall, internal insulation252.0%
Solid wall, partly insulated100.8%
Cavity wall, unfilled60.5%
Cavity wall, internal or external insulation50.4%
Cavity wall, partly insulated30.2%
Cavity wall, filled10.1%
HeatingHomesShare
Gas boiler90671.6%
Electric (storage heaters, panels, boiler)25219.9%
Communal heating755.9%
Heat pump312.4%
LPG10.1%
Other10.1%
Loft / roof insulationHomesShare
No insulation1138.9%
Under 200 mm151.2%
200 mm or more120.9%
Insulated (depth not recorded)22818.0%
Flat or other home above85167.2%
Other473.7%
WindowsHomesShare
Double glazed95075.0%
Single glazed24419.3%
Secondary glazing554.3%
Triple glazed171.3%

Energy rating: B 247 (19.5%) · C 636 (50.2%) · D 287 (22.7%) · E 83 (6.6%) · F 12 (0.9%) · G 1 (0.1%). Houses and bungalows: 2% of the homes; solar panels on 0.2% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 1 January 1991.

Compared with Hackney and England

Share of homesSouth ShoreditchAll 37 areas in HackneyEngland
Solid walls, no insulation52.6%50.5%48.7%
Gas boiler71.6%70.8%66.4%
Rated D–G30.3%—56.5%

Caveats

All conservation areas in Hackney · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker