EPC Price Check

Solar panels, heat pumps and insulation in Charlotteville conservation area

In the Charlotteville conservation area (Guildford), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. 383 homes inside the boundary have an energy certificate: 50.4% are solid-wall homes with no wall insulation, 83.6% heat with a gas boiler and 66.8% are rated D–G; 3 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

383homes with an energy certificate
50.4%solid walls, no insulation
83.6%heated by a gas boiler
3heat pumps

Article 4: Guildford does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Charlotteville

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 383)

WallsHomesShare
Solid wall (brick or stone), no insulation19350.4%
Cavity wall, insulated (as built or unspecified)6918.0%
Cavity wall, unfilled5915.4%
Cavity wall, partly insulated246.3%
Cavity wall, filled236.0%
Modern wall (U-value from the design)51.3%
Other or not known20.5%
Solid wall, external insulation20.5%
Solid wall, internal insulation20.5%
Timber frame20.5%
Cavity wall, internal or external insulation10.3%
Solid wall, insulated10.3%
HeatingHomesShare
Gas boiler32083.6%
Electric (storage heaters, panels, boiler)5313.8%
Communal heating71.8%
Heat pump30.8%
Loft / roof insulationHomesShare
No insulation4612.0%
Under 200 mm14237.1%
200 mm or more5915.4%
Insulated (depth not recorded)4812.5%
Flat or other home above8421.9%
Other41.0%
WindowsHomesShare
Double glazed32584.9%
Single glazed5514.4%
Secondary glazing30.8%

Energy rating: A 1 (0.3%) · B 8 (2.1%) · C 118 (30.8%) · D 180 (47.0%) · E 70 (18.3%) · F 5 (1.3%) · G 1 (0.3%). Houses and bungalows: 62% of the homes; solar panels on 0.5% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 23 January 1990.

Compared with Guildford and England

Share of homesCharlottevilleAll 41 areas in GuildfordEngland
Solid walls, no insulation50.4%39.9%48.7%
Gas boiler83.6%68.7%66.4%
Rated D–G66.8%—56.5%

Caveats

All conservation areas in Guildford · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker