EPC Price Check

Solar panels, heat pumps and insulation in Sun in the Sands conservation area

In the Sun in the Sands conservation area (Greenwich), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 1 listed building; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 222 homes inside the boundary have an energy certificate: 75.7% are solid-wall homes with no wall insulation, 88.7% heat with a gas boiler and 67.6% are rated D–G; 7 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

222homes with an energy certificate
75.7%solid walls, no insulation
88.7%heated by a gas boiler
7heat pumps

Article 4: Greenwich does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Sun in the Sands

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 222)

WallsHomesShare
Solid wall (brick or stone), no insulation16875.7%
Modern wall (U-value from the design)177.7%
Cavity wall, unfilled146.3%
Solid wall, internal insulation94.1%
Cavity wall, insulated (as built or unspecified)52.3%
Other or not known41.8%
Solid wall, insulated20.9%
Timber frame20.9%
Solid wall, external insulation10.5%
HeatingHomesShare
Gas boiler19788.7%
Electric (storage heaters, panels, boiler)177.7%
Heat pump73.2%
LPG10.5%
Loft / roof insulationHomesShare
No insulation3415.3%
Under 200 mm3817.1%
200 mm or more229.9%
Insulated (depth not recorded)209.0%
Flat or other home above9542.8%
Other135.9%
WindowsHomesShare
Double glazed17478.4%
Single glazed4018.0%
Secondary glazing73.2%
Triple glazed10.5%

Energy rating: A 3 (1.4%) · B 15 (6.8%) · C 54 (24.3%) · D 101 (45.5%) · E 40 (18.0%) · F 9 (4.1%). Houses and bungalows: 35% of the homes; solar panels on 0.5% of the certificates. Most common build period on the certificates: 1900-1929.

Compared with Greenwich and England

Share of homesSun in the SandsAll 24 areas in GreenwichEngland
Solid walls, no insulation75.7%48.1%48.7%
Gas boiler88.7%71.9%66.4%
Rated D–G67.6%—56.5%

Caveats

All conservation areas in Greenwich · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker