EPC Price Check

Solar panels, heat pumps and insulation in Hardway conservation area

In the Hardway conservation area (Gosport), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. 112 homes inside the boundary have an energy certificate: 12.5% are solid-wall homes with no wall insulation, 90.2% heat with a gas boiler and 49.1% are rated D–G; 1 has a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

112homes with an energy certificate
12.5%solid walls, no insulation
90.2%heated by a gas boiler
1heat pumps

Article 4: Gosport does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Hardway

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 112)

WallsHomesShare
Cavity wall, insulated (as built or unspecified)2724.1%
Cavity wall, unfilled2522.3%
Cavity wall, filled2017.9%
Solid wall (brick or stone), no insulation1412.5%
Modern wall (U-value from the design)119.8%
Timber frame76.2%
Solid wall, internal insulation43.6%
Cavity wall, partly insulated32.7%
Other or not known10.9%
HeatingHomesShare
Gas boiler10190.2%
Electric (storage heaters, panels, boiler)87.1%
Communal heating21.8%
Heat pump10.9%
Loft / roof insulationHomesShare
No insulation1614.3%
Under 200 mm2724.1%
200 mm or more2925.9%
Insulated (depth not recorded)1210.7%
Flat or other home above2118.8%
Other76.2%
WindowsHomesShare
Double glazed10694.6%
Triple glazed65.4%

Energy rating: A 6 (5.4%) · B 18 (16.1%) · C 33 (29.5%) · D 40 (35.7%) · E 12 (10.7%) · F 1 (0.9%) · G 2 (1.8%). Houses and bungalows: 64% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 1 January 1985.

Compared with Gosport and England

Share of homesHardwayAll 19 areas in GosportEngland
Solid walls, no insulation12.5%11.9%48.7%
Gas boiler90.2%56.4%66.4%
Rated D–G49.1%—56.5%

Caveats

All conservation areas in Gosport · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker