EPC Price Check

Solar panels, heat pumps and insulation in New Romney, High Street conservation area

In the New Romney, High Street conservation area (Folkestone and Hythe), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 49 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 137 homes inside the boundary have an energy certificate: 33.6% are solid-wall homes with no wall insulation, 78.8% heat with a gas boiler and 69.3% are rated D–G; 3 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

137homes with an energy certificate
33.6%solid walls, no insulation
78.8%heated by a gas boiler
3heat pumps

Article 4: Folkestone and Hythe does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in New Romney, High Street

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 137)

WallsHomesShare
Solid wall (brick or stone), no insulation4633.6%
Cavity wall, unfilled2316.8%
Modern wall (U-value from the design)2014.6%
Cavity wall, insulated (as built or unspecified)1712.4%
Cavity wall, filled107.3%
Cavity wall, partly insulated96.6%
Solid wall, internal insulation53.6%
Timber frame32.2%
Cavity wall, internal or external insulation21.5%
Solid wall, insulated21.5%
HeatingHomesShare
Gas boiler10878.8%
Electric (storage heaters, panels, boiler)2216.1%
Communal heating42.9%
Heat pump32.2%
Loft / roof insulationHomesShare
No insulation1712.4%
Under 200 mm3727.0%
200 mm or more4230.7%
Insulated (depth not recorded)1611.7%
Flat or other home above75.1%
Other1813.1%
WindowsHomesShare
Double glazed10677.4%
Single glazed1813.1%
Secondary glazing128.8%
Triple glazed10.7%

Energy rating: B 16 (11.7%) · C 26 (19.0%) · D 56 (40.9%) · E 31 (22.6%) · F 5 (3.6%) · G 3 (2.2%). Houses and bungalows: 67% of the homes; solar panels on 1.5% of the certificates. Most common build period on the certificates: before 1900. Designated: 5 February 1971.

Compared with Folkestone and Hythe and England

Share of homesNew Romney, High StreetAll 21 areas in Folkestone and HytheEngland
Solid walls, no insulation33.6%40.8%48.7%
Gas boiler78.8%69.0%66.4%
Rated D–G69.3%—56.5%

Caveats

All conservation areas in Folkestone and Hythe · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker