EPC Price Check

Solar panels, heat pumps and insulation in Titchfield conservation area

In the Titchfield conservation area (Fareham), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Fareham covers part of this area (about 8% of it) and removes permitted development rights for solar panels on the house, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. The area has 84 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 184 homes inside the boundary have an energy certificate: 49.5% are solid-wall homes with no wall insulation, 97.8% heat with a gas boiler and 71.2% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

184homes with an energy certificate
49.5%solid walls, no insulation
97.8%heated by a gas boiler
0heat pumps

Article 4: An Article 4 direction published by Fareham covers part of this area (about 8% of it) and removes permitted development rights for solar panels on the house, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. (Titchfield)

What needs planning permission in Titchfield

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)Inside the Article 4 part of the area: planning permission needed; elsewhere: no permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Inside the Article 4 part of the area: planning permission needed; elsewhere: prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceInside the Article 4 part of the area: planning permission needed; elsewhere: no permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 184)

WallsHomesShare
Solid wall (brick or stone), no insulation9149.5%
Cavity wall, insulated (as built or unspecified)3619.6%
Cavity wall, filled2111.4%
Cavity wall, unfilled189.8%
Modern wall (U-value from the design)63.3%
Timber frame42.2%
Cavity wall, partly insulated31.6%
Solid wall, internal insulation31.6%
Solid wall, insulated21.1%
HeatingHomesShare
Gas boiler18097.8%
Electric (storage heaters, panels, boiler)31.6%
LPG10.5%
Loft / roof insulationHomesShare
No insulation3016.3%
Under 200 mm6133.2%
200 mm or more6434.8%
Insulated (depth not recorded)137.1%
Flat or other home above105.4%
Other63.3%
WindowsHomesShare
Double glazed13070.7%
Single glazed3418.5%
Secondary glazing2010.9%

Energy rating: B 6 (3.3%) · C 47 (25.5%) · D 87 (47.3%) · E 37 (20.1%) · F 7 (3.8%). Houses and bungalows: 89% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 January 1969.

Compared with Fareham and England

Share of homesTitchfieldAll 13 areas in FarehamEngland
Solid walls, no insulation49.5%28.7%48.7%
Gas boiler97.8%78.9%66.4%
Rated D–G71.2%—56.5%

Caveats

All conservation areas in Fareham · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker