Solar panels, heat pumps and insulation in Riverside conservation area

In the Riverside conservation area (Exeter), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 32 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 608 homes inside the boundary have an energy certificate: 15.3% are solid-wall homes with no wall insulation, 64.1% heat with a gas boiler and 26.2% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

608homes with an energy certificate
15.3%solid walls, no insulation
64.1%heated by a gas boiler
0heat pumps

Article 4: Exeter publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Riverside

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 608)

WallsHomesShare
Cavity wall, insulated (as built or unspecified)23739.0%
Solid wall (brick or stone), no insulation9315.3%
Cavity wall, filled8814.5%
Modern wall (U-value from the design)538.7%
Timber frame406.6%
Other or not known386.2%
Cavity wall, partly insulated325.3%
Solid wall, insulated162.6%
Cavity wall, unfilled71.2%
Solid wall, internal insulation30.5%
Solid wall, external insulation10.2%
HeatingHomesShare
Gas boiler39064.1%
Electric (storage heaters, panels, boiler)20533.7%
Communal heating122.0%
Solid fuel (wood, coal)10.2%
Loft / roof insulationHomesShare
No insulation274.4%
Under 200 mm8413.8%
200 mm or more10116.6%
Insulated (depth not recorded)569.2%
Flat or other home above31451.6%
Other264.3%
WindowsHomesShare
Double glazed56392.6%
Single glazed416.7%
Other20.3%
Secondary glazing20.3%

Energy rating: B 73 (12.0%) · C 376 (61.8%) · D 125 (20.6%) · E 28 (4.6%) · F 3 (0.5%) · G 3 (0.5%). Houses and bungalows: 17% of the homes; solar panels on 0.3% of the certificates. Most common build period on the certificates: 1976-1982. Designated: 22 March 1993.

Compared with Exeter and England

Share of homesRiversideAll 20 areas in ExeterEngland
Solid walls, no insulation15.3%35.2%48.7%
Gas boiler64.1%69.4%66.4%
Rated D–G26.2%—56.5%

Caveats

All conservation areas in Exeter · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker