EPC Price Check

Solar panels, heat pumps and insulation in West End conservation area

In the West End conservation area (Darlington), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 38 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,709 homes inside the boundary have an energy certificate: 40.3% are solid-wall homes with no wall insulation, 84.6% heat with a gas boiler and 52.7% are rated D–G; 1 has a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,709homes with an energy certificate
40.3%solid walls, no insulation
84.6%heated by a gas boiler
1heat pumps

Article 4: Darlington does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in West End

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,709)

WallsHomesShare
Solid wall (brick or stone), no insulation68940.3%
Cavity wall, insulated (as built or unspecified)41624.3%
Cavity wall, filled22012.9%
Cavity wall, unfilled1709.9%
Modern wall (U-value from the design)563.3%
Cavity wall, partly insulated482.8%
Timber frame412.4%
Solid wall, internal insulation331.9%
Solid wall, insulated301.8%
Cavity wall, internal or external insulation30.2%
Other or not known20.1%
Solid wall, partly insulated10.1%
HeatingHomesShare
Gas boiler1,44584.6%
Electric (storage heaters, panels, boiler)1428.3%
Communal heating1166.8%
LPG20.1%
Oil20.1%
Heat pump10.1%
Solid fuel (wood, coal)10.1%
Loft / roof insulationHomesShare
No insulation27816.3%
Under 200 mm24714.5%
200 mm or more40723.8%
Insulated (depth not recorded)1679.8%
Flat or other home above58334.1%
Other271.6%
WindowsHomesShare
Double glazed1,52689.3%
Single glazed1579.2%
Secondary glazing251.5%
Triple glazed10.1%

Energy rating: A 1 (0.1%) · B 118 (6.9%) · C 689 (40.3%) · D 492 (28.8%) · E 342 (20.0%) · F 63 (3.7%) · G 4 (0.2%). Houses and bungalows: 46% of the homes; solar panels on 0.6% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 1 January 1968.

Compared with Darlington and England

Share of homesWest EndAll 17 areas in DarlingtonEngland
Solid walls, no insulation40.3%43.1%48.7%
Gas boiler84.6%73.6%66.4%
Rated D–G52.7%—56.5%

Caveats

All conservation areas in Darlington · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker