EPC Price Check

Solar panels, heat pumps and insulation in St Columb Major conservation area

In the St Columb Major conservation area (Cornwall), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 76 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 305 homes inside the boundary have an energy certificate: 55.7% are solid-wall homes with no wall insulation, 72.5% heat with a gas boiler and 65.2% are rated D–G; 2 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

305homes with an energy certificate
55.7%solid walls, no insulation
72.5%heated by a gas boiler
2heat pumps

Article 4: Cornwall does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in St Columb Major

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 305)

WallsHomesShare
Solid wall (brick or stone), no insulation17055.7%
Timber frame4213.8%
Cavity wall, insulated (as built or unspecified)278.9%
Modern wall (U-value from the design)185.9%
Solid wall, insulated144.6%
Solid wall, internal insulation123.9%
Cavity wall, filled62.0%
Cavity wall, unfilled62.0%
Cavity wall, partly insulated41.3%
Solid wall, partly insulated31.0%
Cavity wall, internal or external insulation20.7%
Other or not known10.3%
HeatingHomesShare
Gas boiler22172.5%
Electric (storage heaters, panels, boiler)7424.3%
Communal heating20.7%
Heat pump20.7%
LPG20.7%
Oil20.7%
Solid fuel (wood, coal)20.7%
Loft / roof insulationHomesShare
No insulation5217.0%
Under 200 mm5317.4%
200 mm or more10634.8%
Insulated (depth not recorded)3812.5%
Flat or other home above3712.1%
Other196.2%
WindowsHomesShare
Double glazed25583.6%
Single glazed4715.4%
Secondary glazing31.0%

Energy rating: B 16 (5.2%) · C 90 (29.5%) · D 105 (34.4%) · E 68 (22.3%) · F 15 (4.9%) · G 11 (3.6%). Houses and bungalows: 72% of the homes; solar panels on 0.7% of the certificates. Most common build period on the certificates: before 1900. Designated: 14 September 1976.

Compared with Cornwall and England

Share of homesSt Columb MajorAll 145 areas in CornwallEngland
Solid walls, no insulation55.7%56.0%48.7%
Gas boiler72.5%51.3%66.4%
Rated D–G65.2%—56.5%

Caveats

All conservation areas in Cornwall · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker