EPC Price Check

Solar panels, heat pumps and insulation in Newlyn conservation area

In the Newlyn conservation area (Cornwall), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 44 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 495 homes inside the boundary have an energy certificate: 76.8% are solid-wall homes with no wall insulation, 74.3% heat with a gas boiler and 82.8% are rated D–G; 10 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

495homes with an energy certificate
76.8%solid walls, no insulation
74.3%heated by a gas boiler
10heat pumps

Article 4: Cornwall does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Newlyn

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 495)

WallsHomesShare
Solid wall (brick or stone), no insulation38076.8%
Cavity wall, unfilled316.3%
Timber frame183.6%
Solid wall, internal insulation173.4%
Cavity wall, insulated (as built or unspecified)163.2%
Solid wall, insulated102.0%
Modern wall (U-value from the design)81.6%
Cavity wall, internal or external insulation51.0%
Cavity wall, filled30.6%
Cavity wall, partly insulated30.6%
Solid wall, external insulation30.6%
Solid wall, partly insulated10.2%
HeatingHomesShare
Gas boiler36874.3%
Electric (storage heaters, panels, boiler)9619.4%
Heat pump102.0%
Solid fuel (wood, coal)91.8%
Communal heating81.6%
LPG30.6%
Oil10.2%
Loft / roof insulationHomesShare
No insulation11723.6%
Under 200 mm14028.3%
200 mm or more12224.6%
Insulated (depth not recorded)6212.5%
Flat or other home above469.3%
Other81.6%
WindowsHomesShare
Double glazed37375.4%
Single glazed10922.0%
Secondary glazing132.6%

Energy rating: B 7 (1.4%) · C 78 (15.8%) · D 190 (38.4%) · E 146 (29.5%) · F 45 (9.1%) · G 29 (5.9%). Houses and bungalows: 80% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 8 June 1970.

Compared with Cornwall and England

Share of homesNewlynAll 145 areas in CornwallEngland
Solid walls, no insulation76.8%56.0%48.7%
Gas boiler74.3%51.3%66.4%
Rated D–G82.8%—56.5%

Caveats

All conservation areas in Cornwall · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker