EPC Price Check

Solar panels, heat pumps and insulation in Camelford conservation area

In the Camelford conservation area (Cornwall), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 20 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 241 homes inside the boundary have an energy certificate: 46.5% are solid-wall homes with no wall insulation, 0.0% heat with a gas boiler and 72.6% are rated D–G; 12 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

241homes with an energy certificate
46.5%solid walls, no insulation
0.0%heated by a gas boiler
12heat pumps

Article 4: Cornwall does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Camelford

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 241)

WallsHomesShare
Solid wall (brick or stone), no insulation11246.5%
Cavity wall, insulated (as built or unspecified)3916.2%
Cavity wall, filled2510.4%
Timber frame156.2%
Solid wall, insulated145.8%
Solid wall, internal insulation125.0%
Modern wall (U-value from the design)93.7%
Cavity wall, unfilled52.1%
Cavity wall, partly insulated41.7%
Other or not known31.2%
Cavity wall, internal or external insulation20.8%
Solid wall, external insulation10.4%
HeatingHomesShare
Electric (storage heaters, panels, boiler)16267.2%
Oil3815.8%
Heat pump125.0%
Communal heating104.1%
Solid fuel (wood, coal)104.1%
LPG93.7%
Loft / roof insulationHomesShare
No insulation2410.0%
Under 200 mm3916.2%
200 mm or more8334.4%
Insulated (depth not recorded)3313.7%
Flat or other home above5422.4%
Other83.3%
WindowsHomesShare
Double glazed22392.5%
Single glazed135.4%
Secondary glazing41.7%
Triple glazed10.4%

Energy rating: A 1 (0.4%) · B 15 (6.2%) · C 50 (20.7%) · D 55 (22.8%) · E 82 (34.0%) · F 23 (9.5%) · G 15 (6.2%). Houses and bungalows: 50% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 April 1986.

Compared with Cornwall and England

Share of homesCamelfordAll 145 areas in CornwallEngland
Solid walls, no insulation46.5%56.0%48.7%
Gas boiler0.0%51.3%66.4%
Rated D–G72.6%—56.5%

Caveats

All conservation areas in Cornwall · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker