EPC Price Check

Solar panels, heat pumps and insulation in The Poets conservation area

In the The Poets conservation area (Cheltenham), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. 394 homes inside the boundary have an energy certificate: 2.3% are solid-wall homes with no wall insulation, 93.1% heat with a gas boiler and 70.3% are rated D–G; 2 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

394homes with an energy certificate
2.3%solid walls, no insulation
93.1%heated by a gas boiler
2heat pumps

Article 4: Cheltenham publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in The Poets

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 394)

WallsHomesShare
Cavity wall, filled23659.9%
Cavity wall, unfilled11629.4%
Cavity wall, insulated (as built or unspecified)133.3%
Other or not known102.5%
Solid wall (brick or stone), no insulation92.3%
Modern wall (U-value from the design)71.8%
Cavity wall, internal or external insulation20.5%
Cavity wall, partly insulated10.3%
HeatingHomesShare
Gas boiler36793.1%
Electric (storage heaters, panels, boiler)143.6%
Communal heating112.8%
Heat pump20.5%
Loft / roof insulationHomesShare
No insulation358.9%
Under 200 mm15840.1%
200 mm or more16441.6%
Insulated (depth not recorded)246.1%
Flat or other home above61.5%
Other71.8%
WindowsHomesShare
Double glazed38096.4%
Single glazed143.6%

Energy rating: A 3 (0.8%) · B 8 (2.0%) · C 106 (26.9%) · D 222 (56.3%) · E 49 (12.4%) · F 5 (1.3%) · G 1 (0.3%). Houses and bungalows: 94% of the homes; solar panels on 4.1% of the certificates. Most common build period on the certificates: 1930-1949. Designated: 1 May 2001.

Compared with Cheltenham and England

Share of homesThe PoetsAll 7 areas in CheltenhamEngland
Solid walls, no insulation2.3%50.0%48.7%
Gas boiler93.1%72.5%66.4%
Rated D–G70.3%—56.5%

Caveats

All conservation areas in Cheltenham · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker