EPC Price Check

Solar panels, heat pumps and insulation in the Tyler Hill . Registered conservation area

In the the Tyler Hill . Registered conservation area (Canterbury), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Canterbury covers this area, but the published data does not say which rights it removes — check the direction before any work. The area has 6 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 167 homes inside the boundary have an energy certificate: 15.0% are solid-wall homes with no wall insulation, 84.4% heat with a gas boiler and 64.1% are rated D–G; 5 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

167homes with an energy certificate
15.0%solid walls, no insulation
84.4%heated by a gas boiler
5heat pumps

Article 4: An Article 4 direction published by Canterbury covers this area, but the published data does not say which rights it removes — check the direction before any work. (11 CALAIS HILL, TYLER HILL; 9 CALAIS HILL, TYLER HILL; Canterbury and surrounding area. Dated 25.02.2015 effective 25.02.2016)

What needs planning permission in the Tyler Hill . Registered

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 167)

WallsHomesShare
Cavity wall, filled7544.9%
Cavity wall, unfilled2917.4%
Solid wall (brick or stone), no insulation2515.0%
Cavity wall, insulated (as built or unspecified)169.6%
Modern wall (U-value from the design)74.2%
Timber frame53.0%
Cavity wall, partly insulated31.8%
Solid wall, insulated31.8%
Cavity wall, internal or external insulation21.2%
Other or not known10.6%
Solid wall, internal insulation10.6%
HeatingHomesShare
Gas boiler14184.4%
Electric (storage heaters, panels, boiler)116.6%
Oil84.8%
Heat pump53.0%
Solid fuel (wood, coal)21.2%
Loft / roof insulationHomesShare
No insulation95.4%
Under 200 mm5633.5%
200 mm or more6538.9%
Insulated (depth not recorded)2112.6%
Flat or other home above95.4%
Other74.2%
WindowsHomesShare
Double glazed15592.8%
Secondary glazing63.6%
Single glazed31.8%
Triple glazed31.8%

Energy rating: A 2 (1.2%) · B 10 (6.0%) · C 48 (28.7%) · D 76 (45.5%) · E 31 (18.6%). Houses and bungalows: 88% of the homes; solar panels on 3.0% of the certificates. Most common build period on the certificates: 1950-1966. Designated: 28 February 1995.

Compared with Canterbury and England

Share of homesthe Tyler Hill . RegisteredAll 98 areas in CanterburyEngland
Solid walls, no insulation15.0%36.5%48.7%
Gas boiler84.4%73.7%66.4%
Rated D–G64.1%—56.5%

Caveats

All conservation areas in Canterbury · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker