Solar panels, heat pumps and insulation in West End Green conservation area

In the West End Green conservation area (Camden), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Camden covers this area, but the published data does not say which rights it removes — check the direction before any work. The area has 6 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,513 homes inside the boundary have an energy certificate: 86.1% are solid-wall homes with no wall insulation, 75.2% heat with a gas boiler and 54.2% are rated D–G; 2 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,513homes with an energy certificate
86.1%solid walls, no insulation
75.2%heated by a gas boiler
2heat pumps

Article 4: An Article 4 direction published by Camden covers this area, but the published data does not say which rights it removes — check the direction before any work. (Basements; Commercial, Business, and Service (Use Class E) to residential (Use Class C3) (outside CAZ))

What needs planning permission in West End Green

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,513)

WallsHomesShare
Solid wall (brick or stone), no insulation1,30286.1%
Solid wall, internal insulation795.2%
Timber frame604.0%
Cavity wall, insulated (as built or unspecified)261.7%
Other or not known130.9%
Modern wall (U-value from the design)90.6%
Cavity wall, unfilled80.5%
Cavity wall, filled50.3%
Solid wall, insulated50.3%
Solid wall, partly insulated40.3%
Cavity wall, partly insulated20.1%
HeatingHomesShare
Gas boiler1,13875.2%
Communal heating26117.3%
Electric (storage heaters, panels, boiler)1127.4%
Heat pump20.1%
Loft / roof insulationHomesShare
No insulation26617.6%
Under 200 mm614.0%
200 mm or more432.8%
Insulated (depth not recorded)1197.9%
Flat or other home above1,01467.1%
Other90.6%
WindowsHomesShare
Double glazed81153.6%
Single glazed59139.1%
Secondary glazing1097.2%
Triple glazed20.1%

Energy rating: B 21 (1.4%) · C 672 (44.4%) · D 596 (39.4%) · E 197 (13.0%) · F 22 (1.5%) · G 5 (0.3%). Houses and bungalows: 5% of the homes; solar panels on 0.1% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 1 March 1993.

Compared with Camden and England

Share of homesWest End GreenAll 40 areas in CamdenEngland
Solid walls, no insulation86.1%67.1%48.7%
Gas boiler75.2%67.5%66.4%
Rated D–G54.2%—56.5%

Caveats

All conservation areas in Camden · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker