EPC Price Check

Solar panels, heat pumps and insulation in Hebden Bridge (09/0004/CONARA) conservation area

In the Hebden Bridge conservation area (Calderdale), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Calderdale covers part of this area (about 0% of it) but deals with other things (such as changes of use); it does not change the rules below. The area has 58 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,051 homes inside the boundary have an energy certificate: 69.2% are solid-wall homes with no wall insulation, 92.8% heat with a gas boiler and 72.6% are rated D–G; 8 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,051homes with an energy certificate
69.2%solid walls, no insulation
92.8%heated by a gas boiler
8heat pumps

Article 4: An Article 4 direction published by Calderdale covers part of this area (about 0% of it) but deals with other things (such as changes of use); it does not change the rules below. (1 Eiffel Street, Hebden Bridge.; 35 Hangingroyd Lane, Hebden Bridge.; 4 Birchcliffe Road, Hebden Bridge.; 5 Melbourne Street, Hebden Bridge.)

What needs planning permission in Hebden Bridge

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,051)

WallsHomesShare
Solid wall (brick or stone), no insulation72769.2%
Cavity wall, unfilled10610.1%
Modern wall (U-value from the design)706.7%
Solid wall, insulated494.7%
Cavity wall, insulated (as built or unspecified)373.5%
Solid wall, internal insulation292.8%
Timber frame171.6%
Solid wall, partly insulated50.5%
Cavity wall, internal or external insulation40.4%
Cavity wall, partly insulated40.4%
Cavity wall, filled20.2%
Other or not known10.1%
HeatingHomesShare
Gas boiler97592.8%
Electric (storage heaters, panels, boiler)535.0%
Solid fuel (wood, coal)111.0%
Heat pump80.8%
Communal heating40.4%
Loft / roof insulationHomesShare
No insulation44542.4%
Under 200 mm535.0%
200 mm or more666.3%
Insulated (depth not recorded)20319.3%
Flat or other home above23422.3%
Other494.7%
WindowsHomesShare
Double glazed91086.6%
Single glazed12111.5%
Secondary glazing151.4%
Triple glazed50.5%

Energy rating: B 46 (4.4%) · C 242 (23.0%) · D 430 (40.9%) · E 285 (27.1%) · F 36 (3.4%) · G 12 (1.1%). Houses and bungalows: 67% of the homes; solar panels on 0.2% of the certificates. Most common build period on the certificates: before 1900. Designated: 25 February 1992.

Compared with Calderdale and England

Share of homesHebden BridgeAll 24 areas in CalderdaleEngland
Solid walls, no insulation69.2%59.1%48.7%
Gas boiler92.8%83.5%66.4%
Rated D–G72.6%—56.5%

Caveats

All conservation areas in Calderdale · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker