EPC Price Check

Solar panels, heat pumps and insulation in Thorpe End Garden Village conservation area

In the Thorpe End Garden Village conservation area (Broadland), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. 86 homes inside the boundary have an energy certificate: 7% are solid-wall homes with no wall insulation, 87% heat with a gas boiler and 71% are rated D–G; 2 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

86homes with an energy certificate
7%solid walls, no insulation
87%heated by a gas boiler
2heat pumps

Article 4: Broadland publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Thorpe End Garden Village

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 86)

WallsHomesShare
Cavity wall, filled4249%
Cavity wall, unfilled2529%
Cavity wall, insulated (as built or unspecified)89%
Solid wall (brick or stone), no insulation67%
Modern wall (U-value from the design)33%
Cavity wall, internal or external insulation11%
Cavity wall, partly insulated11%
HeatingHomesShare
Gas boiler7587%
Electric (storage heaters, panels, boiler)910%
Heat pump22%
Loft / roof insulationHomesShare
No insulation78%
Under 200 mm3541%
200 mm or more2934%
Insulated (depth not recorded)1012%
Flat or other home above11%
Other45%
WindowsHomesShare
Double glazed8599%
Single glazed11%

Energy rating: A 1 (1%) · B 2 (2%) · C 22 (26%) · D 46 (53%) · E 12 (14%) · F 3 (3%). Houses and bungalows: 88% of the homes; solar panels on 0% of the certificates. Most common build period on the certificates: 1930-1949. Designated: 1 January 2010.

Compared with Broadland and England

Share of homesThorpe End Garden VillageAll 32 areas in BroadlandEngland
Solid walls, no insulation7%38.4%48.7%
Gas boiler87%56.4%66.4%
Rated D–G71%—56.5%

Caveats

All conservation areas in Broadland · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker