Solar panels, heat pumps and insulation in Hampstead Garden Suburb conservation area

In the Hampstead Garden Suburb conservation area (Barnet), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Barnet covers this area and removes permitted development rights for solar panels on the house, ground source heat pumps, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), painting the outside, so there these need planning permission too. The area has 290 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 3,679 homes inside the boundary have an energy certificate: 72.8% are solid-wall homes with no wall insulation, 93.4% heat with a gas boiler and 75.6% are rated D–G; 41 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

3,679homes with an energy certificate
72.8%solid walls, no insulation
93.4%heated by a gas boiler
41heat pumps

Article 4: An Article 4 direction published by Barnet covers this area and removes permitted development rights for solar panels on the house, ground source heat pumps, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), painting the outside, so there these need planning permission too. (Article 4 Small Houses in Multiple Occupation (HMO) Area 1; Article 4 for Hampstead Garden Suburb CA Area 1; Article 4 for Hampstead Garden Suburb CA Area 2 Spaniards End)

What needs planning permission in Hampstead Garden Suburb

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)Planning permission needed (an Article 4 direction here removes this right)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Planning permission needed (an Article 4 direction here removes this right)Part 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 3,679)

WallsHomesShare
Solid wall (brick or stone), no insulation2,67772.8%
Cavity wall, unfilled46712.7%
Timber frame1203.3%
Cavity wall, insulated (as built or unspecified)1133.1%
Modern wall (U-value from the design)1052.9%
Solid wall, internal insulation591.6%
Cavity wall, filled531.4%
Solid wall, insulated371.0%
Other or not known250.7%
Cavity wall, partly insulated130.4%
Cavity wall, internal or external insulation80.2%
Solid wall, external insulation10.0%
Solid wall, partly insulated10.0%
HeatingHomesShare
Gas boiler3,43793.4%
Communal heating1163.2%
Electric (storage heaters, panels, boiler)802.2%
Heat pump411.1%
LPG30.1%
Solid fuel (wood, coal)20.1%
Loft / roof insulationHomesShare
No insulation1,12730.6%
Under 200 mm84022.8%
200 mm or more3018.2%
Insulated (depth not recorded)43611.9%
Flat or other home above88424.0%
Other902.4%
WindowsHomesShare
Double glazed1,48840.4%
Single glazed1,32536.0%
Secondary glazing86123.4%
Triple glazed50.1%

Energy rating: A 1 (0.0%) · B 115 (3.1%) · C 781 (21.2%) · D 1,767 (48.0%) · E 855 (23.2%) · F 147 (4.0%) · G 13 (0.4%). Houses and bungalows: 60% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 20 December 1968.

Compared with Barnet and England

Share of homesHampstead Garden SuburbAll 16 areas in BarnetEngland
Solid walls, no insulation72.8%48.2%48.7%
Gas boiler93.4%84.8%66.4%
Rated D–G75.6%—56.5%

Caveats

All conservation areas in Barnet · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker